Literature DB >> 15648464

Influence of collimator size on three-dimensional conformal radiotherapy of the cyberknife.

Yasushi Hamamoto1, Toshiharu Manabe, Osamu Nishizaki, Tadaaki Takahashi, Nobuko Isshiki, Suetoshi Murayama, Kyoichiro Nishina, Masakichi Umeda.   

Abstract

PURPOSE: In stereotactic conformal radiotherapy of the CyberKnife, multiple narrow beams from a cylindrical collimator are delivered to a planning target volume (PTV) without an isocenter by inverse planning. The influence of collimator size on stereotactic conformal radiotherapy was examined.
MATERIALS AND METHODS: Five targets including two spherical targets (2.1 ml, 16.4 ml), an ellipsoidal target (2.9 ml), and two irregularly shaped targets (1.6 ml, 6.6 ml) were evaluated. Conformity and homogeneity of dose distribution, doses covering 95% volume of PTVs (D95), dose volume histograms (DVHs), and patterns of dose distribution were investigated in relation to collimator size for each target. We evaluated conformity and homogeneity using VD95/PTV (VD95 = volume covered by a D95 isodose surface) and Dmax/Dmin (Dmax, Dmin = maximum and minimum dose within the PTV, respectively), respectively.
RESULTS: Conformity and homogeneity were not significantly influenced by collimator size. By using a considerably smaller collimator compared with the minor axis of the target the central dose of the target fell by less than 10% and D95 often decreased slightly.
CONCLUSION: In stereotactic conformal radiotherapy of the CyberKnife, a smaller collimator tended to reduce the central dose and D95. These characteristics of the CyberKnife system should be considered.

Mesh:

Year:  2004        PMID: 15648464

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  3 in total

Review 1.  The role of simulation in neurosurgery.

Authors:  Roberta Rehder; Muhammad Abd-El-Barr; Kristopher Hooten; Peter Weinstock; Joseph R Madsen; Alan R Cohen
Journal:  Childs Nerv Syst       Date:  2015-10-05       Impact factor: 1.475

2.  CyberKnife radiosurgery in the treatment of complex skull base tumors: analysis of treatment planning parameters.

Authors:  Sean P Collins; Nicholas D Coppa; Ying Zhang; Brian T Collins; Donald A McRae; Walter C Jean
Journal:  Radiat Oncol       Date:  2006-12-16       Impact factor: 3.481

3.  A phantom study to determine the optimum size of a single collimator for shortening the treatment time in CyberKnife stereotactic radiosurgery of spherical targets.

Authors:  Sudahar Harikrishnaperumal; Gopalakrishna Kurup; Murali Venkatraman; Velmurugan Jagadeesan
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  3 in total