Literature DB >> 15647076

Standardized on-slide control for quality assurance in the immunohistochemical assessment of therapeutic target molecules in breast cancer.

Michael Mengel1, Katrin Hebel, Hans Kreipe, Reinhard von Wasielewski.   

Abstract

Individualization and optimization of risk-adapted therapy in breast cancer requires molecular profiling of individual cancer specimens. In tissues of heterogeneous cellular composition, such as mammary tissue, cancer prognostic markers and potential therapeutic target molecules are preferentially detected by in situ techniques such as immunohistochemistry. The more therapy decisions are based on immunohistochemical findings, the more histopathologists are confronted with the demand to establish standardized procedures that enable reproducible evaluation independent from the investigating laboratory. Disappointing results of recent national and international immunohistochemistry trials for steroid receptor and HER-2 analysis in breast cancer underline the need to act now beyond recommendations and well-formulated guidelines for standardization. In order to ensure staining quality in every individual immunohistochemical analysis, we have developed an on-slide control with standardized samples which are placed on every slide of a therapy-decisive stain together with the tissue of interest. Novel mini tissue microarrays were constructed comprising cell lines as standardized controls, indicating the sensitivity and reliability of the staining procedure. Standardized control material on the same slide as the patient's specimen require neither additional reagents nor time and are automatically archived on the diagnostic slide to prove the quality of staining even after years.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15647076     DOI: 10.1111/j.1075-122X.2005.21445.x

Source DB:  PubMed          Journal:  Breast J        ISSN: 1075-122X            Impact factor:   2.431


  5 in total

1.  Banff Initiative for Quality Assurance in Transplantation (BIFQUIT): reproducibility of polyomavirus immunohistochemistry in kidney allografts.

Authors:  B Adam; P Randhawa; S Chan; G Zeng; H Regele; Y B Kushner; R B Colvin; J Reeve; M Mengel
Journal:  Am J Transplant       Date:  2014-08-04       Impact factor: 8.086

2.  Quality assessment of HER2 testing by monitoring of positivity rates.

Authors:  Harald Choritz; Guntram Büsche; Hans Kreipe
Journal:  Virchows Arch       Date:  2011-08-02       Impact factor: 4.064

Review 3.  Overview on Techniques to Construct Tissue Arrays with Special Emphasis on Tissue Microarrays.

Authors:  Ulrich Vogel
Journal:  Microarrays (Basel)       Date:  2014-04-17

4.  Spheroid arrays for high-throughput single-cell analysis of spatial patterns and biomarker expression in 3D.

Authors:  Delyan P Ivanov; Anna M Grabowska
Journal:  Sci Rep       Date:  2017-01-30       Impact factor: 4.379

Review 5.  Quality control in molecular immunohistochemistry.

Authors:  Lawrence D True
Journal:  Histochem Cell Biol       Date:  2008-07-22       Impact factor: 4.304

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.