Comparison of ECG-gated rectilinear vs. real-time radial K-space sampling schemes in cine True-FISP cardiac MRI.

Daniel T Boll1, Elmar M Merkle, Danielle M Seaman, Robert C Gilkeson, Andrew P Larson, Orlando P Simonetti, Jeffrey L Duerk, Jonathan S Lewin.   

Abstract

PURPOSE: To compare three k-space sampling schemes in cine True-FISP cardiac magnetic resonance imaging and to evaluate changes in calculated quantitative functional cardiac parameters as a function of underlying k-space sampling techniques.
MATERIAL AND METHODS: Using a 1.5 T MR imaging system (Magnetom Sonata, Siemens Medical Solutions, Erlangen, Germany), three k-space data-sampling schemes: rectilinear (2.96 ms/1.58 ms/70 degrees /12 s TR/TE/FA/AcquisitionTime), and two radial k-space acquisitions, with filtered back-projection (RADIAL) (2.45 ms/1.25 ms/ 50 degrees /3.3 s TR/TE/FA/AT), and steady-state projection imaging with dynamic echotrain readout (SPIDER) (3.39 ms/1.62 ms/55 degrees /1.8 s TR/TE/FA/AT) of a True-FISP sequence were applied in 10 healthy volunteers. Long- and short-axis breath-hold series were acquired and signal-to-noise ratios (SNR) for blood and myocardium were determined, as was contrast-to-noise ratios (CNR). Quantitative cardiac functional analysis included: determination of end-systolic/end-diastolic volumes, ejection fraction, and left ventricular mass. Functional analysis was performed by two independent readers three times for each volunteer and k-space sampling strategy. Statistical analysis evaluated the accuracy of the measurements obtained from each of the three sampling techniques and the intra- and interobserver reliability.
RESULTS: Intraobserver and interobserver reliability measures of functional data were homogeneous without statistically significant differences. Intraobserver correlation coefficients ranged from 0.94-0.99; interobserver correlation coefficients ranged from 0.97-0.99. Direct comparison of SPIDER- and RADIAL-sampled True-FISP sequences showed no statistically significant differences in measured functional parameters with interstudy correlation coefficients from 0.88-0.98. RADIAL and SPIDER images had better temporal resolution and were qualitatively judged to provide superior wall/blood border definition. Statistically significant differences were identified in each volumetric functional parameter when results from the rectilinear sampling acquisitions were compared with either radial or SPIDER sampling techniques. RADIAL and SPIDER results were consistently higher than volumetric measures obtained from the rectilinear data set.
CONCLUSION: Employing faster sampling schemes led to enhanced signal homogeneity while maintaining the necessary CNR for estimation of functional cardiac parameters. Enhanced signal homogeneity and maintained CNR will most likely improve the accuracy of the cardiac functional parameter determination.

Entities:  

Mesh:

Year:  2004        PMID: 15646882     DOI: 10.1081/jcmr-200036124

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  5 in total

1.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

2.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

3.  Real-time free-breathing cardiac imaging with self-calibrated through-time radial GRAPPA.

Authors:  Ozan Sayin; Haris Saybasili; M Muz Zviman; Mark Griswold; Henry Halperin; Nicole Seiberlich; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2016-03-10       Impact factor: 4.668

4.  User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias.

Authors:  Francisco Contijoch; Walter R T Witschey; Kelly Rogers; Hannah Rears; Michael Hansen; Paul Yushkevich; Joseph Gorman; Robert C Gorman; Yuchi Han
Journal:  J Cardiovasc Magn Reson       Date:  2015-05-21       Impact factor: 5.364

Review 5.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364