Literature DB >> 15645462

Evaluation of noninvasive hemoglobin monitoring for hematological disorders.

Hiroshi Kanashima1, Takahisa Yamane, Takayuki Takubo, Tomio Kamitani, Masayuki Hino.   

Abstract

The Astrim is a noninvasive hemoglobin monitoring device that uses near-infrared radiation. We studied the usefulness of this device for patients with hematological disorders. We measured hemoglobin levels 309 times in 140 subjects, using an automated hematology analyzer (K-4500) and the Astrim. The coefficient of correlation between Hb levels with the K-4500 (K-Hb) and the Astrim (A-Hb) was r = 0.591 (P < 0.001). The coefficient of correlation between A-Hb and K-Hb from 174 specimens with anemia and 135 without anemia was r = 0.531 (P < 0.001) and r = 0.345 (P < 0.001), respectively. In the 309 specimens, the Astrim showed a diagnostic sensitivity and specificity for anemia of 78.3% and 69.0%, respectively. While the r-values, sensitivity, and specificity were passable, they appeared to be insufficient for an accurate evaluation. We believe this was caused by the measurement conditions (i.e., the finger selected for measurement, the finger position in relation to the CCD camera, and the finger temperature). On the other hand, the precision test results were good. Therefore, if careful attention is paid to measurement conditions, the noninvasive Astrim is clinically useful for continuous hemoglobin monitoring of hematological disorders and patients with hemorrhagic diseases, such as perioperative hemorrhage and gastrointestinal bleeding. However, it is difficult to determine Hb concentrations in one measurement using the Astrim because the r-values, sensitivity, and specificity are insufficient for accurate evaluations of in-patients, particularly patients with advanced diseases. Therefore, we believe it is necessary to improve the system so that A-Hb can be accurately determined in one measurement. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15645462      PMCID: PMC6807845          DOI: 10.1002/jcla.20046

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  9 in total

1.  Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects.

Authors:  Kirill V Larin; Mohsen S Eledrisi; Massoud Motamedi; Rinat O Esenaliev
Journal:  Diabetes Care       Date:  2002-12       Impact factor: 19.112

2.  Non invasive local cerebral oxygenation monitoring using a combination of light and ultrasound.

Authors:  A Lev; Z Kotler; B Sfez; J Soustiel; M Feinsod
Journal:  Acta Neurochir Suppl       Date:  2002

3.  Near-infrared spectrophotometry: a new dimension in clinical chemistry.

Authors:  J W Hall; A Pollard
Journal:  Clin Chem       Date:  1992-09       Impact factor: 8.327

Review 4.  Near-infrared spectroscopy: theory and applications.

Authors:  J A Wahr; K K Tremper; S Samra; D T Delpy
Journal:  J Cardiothorac Vasc Anesth       Date:  1996-04       Impact factor: 2.628

5.  Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters.

Authors:  F F Jöbsis
Journal:  Science       Date:  1977-12-23       Impact factor: 47.728

6.  The definition of anemia in older persons.

Authors:  G J Izaks; R G Westendorp; D L Knook
Journal:  JAMA       Date:  1999-05-12       Impact factor: 56.272

7.  Reproducibility of the blood flow index as noninvasive, bedside estimation of cerebral blood flow.

Authors:  Bendicht P Wagner; Susanne Gertsch; Roland A Ammann; Juerg Pfenninger
Journal:  Intensive Care Med       Date:  2003-01-21       Impact factor: 17.440

8.  Noninvasive monitoring of cerebral oxygenation during vasomotor reactivity tests by a new near-infrared spectroscopy device.

Authors:  Christoph Terborg; Thomas Birkner; Bärbel Schack; Cornelius Weiller; Joachim Röther
Journal:  Cerebrovasc Dis       Date:  2003       Impact factor: 2.762

9.  Noninvasive monitoring of hemoglobin. The effects of WBC counts on measurement.

Authors:  Katsuyasu Saigo; Shion Imoto; Makoto Hashimoto; Hisashi Mito; Junko Moriya; Tadanobu Chinzei; Yoshitsugu Kubota; Shigehiro Numada; Toshiyuki Ozawa; Shunichi Kumagai
Journal:  Am J Clin Pathol       Date:  2004-01       Impact factor: 2.493

  9 in total
  1 in total

1.  Lower peripheral circulation in eumenorrheic young women with premenstrual symptoms.

Authors:  Tamaki Matsumoto; Takahisa Ushiroyama; Noriyuki Tatsumi
Journal:  Biopsychosoc Med       Date:  2007-03-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.