Literature DB >> 15643665

A dual-electrode approach for highly selective detection of glucose based on diffusion layer theory: experiments and simulation.

Kang Wang1, Dai Zhang, Ting Zhou, Xing-Hua Xia.   

Abstract

A dual-electrode configuration for the highly selective detection of glucose in the diffusion layer of the substrate electrode is presented. In this approach, a glassy carbon electrode (GCE, substrate) modified with a conductive layer of glucose oxidase/Nafion/graphite (GNG) was used to create an interference-free region in its diffusion layer by electrochemical depletion of interfering electroactive species. A Pt microelectrode (tip, 5 microm in radius) was located in the diffusion layer of the GNG-modified GCE (GNG-G) with the help of scanning electrochemical microscopy. Consequently, the tip of the electrode could sense glucose selectively by detecting the amount of hydrogen peroxide (H2O2) formed from the oxidization of glucose on the glucose oxidase layer. The influences of parameters, including tip-substrate distance, substrate potential, and electrolyzing time, on the interference-removing efficiency of this dual-electrode approach have been investigated systematically. When the electrolyzing time was 30 s, the tip-substrate distance was 1.8 a (9.0 microm) (where a is the radius of the tip electrode), the potentials of the tip and substrate electrodes were 0.7 V and 0.4 V, respectively, and a mixture of ascorbic acid (0.3 mM), uric acid (0.3 mM), and 4-acetaminophen (0.3 mM) had no influence on the glucose detection. In addition, the current-time responses of the tip electrode at different tip-substrate distances in a solution containing interfering species were numerically simulated. The results from the simulation are in good agreement with the experimental data. This research provides a concept of detection in the diffusion layer of a substrate electrode, as an interference-free region, for developing novel microelectrochemical devices.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15643665     DOI: 10.1002/chem.200400587

Source DB:  PubMed          Journal:  Chemistry        ISSN: 0947-6539            Impact factor:   5.236


  1 in total

1.  Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon.

Authors:  Yi-Jae Lee; Dae-Joon Park; Jae-Yeong Park; Younghun Kim
Journal:  Sensors (Basel)       Date:  2008-10-01       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.