Literature DB >> 1564319

Magnetic bead antigen capture enzyme-linked immunoassay in microtitre trays for rapid detection of schistosomal circulating anodic antigen.

S G Gundersen1, I Haagensen, T O Jonassen, K J Figenschau, N de Jonge, A M Deelder.   

Abstract

We have developed a new magnetic bead antigen capture enzyme-linked immunoassay for the detection of schistosomal circulating anodic antigen. The assay utilizes IgG1 monoclonal antibody coated monodisperse magnetic beads in microtitre trays fitted to a special magnet. The total test time was found to be 1-2 h, using 0.05 mg beads per well. The lower detection level was 0.7 ng AWA-TCA per ml (approximately 0.07 ng CAA per ml). Validation by sera from uninfected and Schistosoma mansoni infected Africans and Norwegians resulted in an assay specificity of 100% and sensitivity was close to 90% for cases excreting more than 100 eggs per gram faeces. At such clinically relevant levels the inter-assay CV was below 10% and photometric absorbance correlated to antigen levels was nearly linear. There was a significant correlation between the magnetic bead EIA absorbance values and the titres obtained using the previously established ELISA. The new bead assay, however, was easier and less laborious because TCA pretreatment and the titration of positive results were unnecessary.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1564319     DOI: 10.1016/0022-1759(92)90151-i

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  11 in total

1.  Evaluation of an IgY-based immunomagnetic enzyme-linked immunosorbent assay system for detection of circulating Schistosoma japonicum antigen in serum samples from patients in China.

Authors:  Jia-hui Lei; Bing-tao Su; Hong Xu; Ji-long Shen; Xiao-hong Guan; Zhen-qing Feng; Yong-long Li; Ming-xing Xu; Wen-qi Liu
Journal:  Am J Trop Med Hyg       Date:  2011-12       Impact factor: 2.345

2.  Flow-orthogonal bead oscillation in a microfluidic chip with a magnetic anisotropic flux-guide array.

Authors:  Stijn van Pelt; Roy Derks; Marco Matteucci; Mikkel Fougt Hansen; Andreas Dietzel
Journal:  Biomed Microdevices       Date:  2011-04       Impact factor: 2.838

Review 3.  Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

Authors:  Eleanor A Ochodo; Gowri Gopalakrishna; Bea Spek; Johannes B Reitsma; Lisette van Lieshout; Katja Polman; Poppy Lamberton; Patrick M M Bossuyt; Mariska M G Leeflang
Journal:  Cochrane Database Syst Rev       Date:  2015-03-11

4.  Experimental study for early diagnosis of prepatent schistosomiasis mansoni by detection of free circulating DNA in serum.

Authors:  Hesham Mohammed Hussein; Manar Mahmoud El-Tonsy; Rania Ayman Tawfik; Sabah Abd-El-Ghany Ahmed
Journal:  Parasitol Res       Date:  2012-07       Impact factor: 2.289

5.  Rapid detection of a Schistosoma mansoni circulating antigen excreted in urine of infected individuals by using a monoclonal antibody.

Authors:  A M Attallah; H Ismail; S A El Masry; H Rizk; A Handousa; M El Bendary; A Tabll; F Ezzat
Journal:  J Clin Microbiol       Date:  1999-02       Impact factor: 5.948

6.  Magnetic affinity enzyme-linked immunoassay for diagnosis of Schistosomiasis japonicum in persons with low-intensity infection.

Authors:  Qin Yu; Hai Yang; Youmei Feng; Yanhong Zhu; Xiangliang Yang
Journal:  Am J Trop Med Hyg       Date:  2012-08-06       Impact factor: 2.345

Review 7.  Magnetic separation techniques in diagnostic microbiology.

Authors:  O Olsvik; T Popovic; E Skjerve; K S Cudjoe; E Hornes; J Ugelstad; M Uhlén
Journal:  Clin Microbiol Rev       Date:  1994-01       Impact factor: 26.132

Review 8.  Development of "-omics" research in Schistosoma spp. and -omics-based new diagnostic tools for schistosomiasis.

Authors:  Shuqi Wang; Wei Hu
Journal:  Front Microbiol       Date:  2014-06-26       Impact factor: 5.640

9.  Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer.

Authors:  Yanli Chang; Jianjun Xu; Qingyun Zhang
Journal:  Oncol Lett       Date:  2017-07-26       Impact factor: 2.967

10.  Detection of Schistosoma mansoni eggs in feces through their interaction with paramagnetic beads in a magnetic field.

Authors:  Candida Fagundes Teixeira; Erli Neuhauss; Renata Ben; Juliano Romanzini; Carlos Graeff-Teixeira
Journal:  PLoS Negl Trop Dis       Date:  2007-11-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.