Literature DB >> 15642568

Clinical variables predicting inappropriate use of implantable cardioverter-defibrillator in patients with coronary heart disease or nonischemic dilated cardiomyopathy.

Dominic A M J Theuns1, A Peter J Klootwijk, Maarten L Simoons, Luc J Jordaens.   

Abstract

Inappropriate therapy is a common clinical problem in recipients of implantable cardioverter-defibrillators (ICDs). The present study evaluated whether clinical characteristics could predict inappropriate ICD therapy due to atrial tachyarrhythmias in a series of 260 patients.

Entities:  

Mesh:

Year:  2005        PMID: 15642568     DOI: 10.1016/j.amjcard.2004.09.017

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Does the rate of inappropriate therapy differ in implantable cardioverter-defibrillators from different manufacturers?

Authors:  Arash Arya; Majid Haghjoo; Zahra Emkanjoo; Mohammad Reza Dehghani; Mohammad Ali Sadr-Ameli
Journal:  J Interv Card Electrophysiol       Date:  2007-01-17       Impact factor: 1.900

2.  Multicenter automatic defibrillator implantation trial: reduce inappropriate therapy (MADIT-RIT): background, rationale, and clinical protocol.

Authors:  Claudio Schuger; James P Daubert; Mary W Brown; David Cannom; N A Mark Estes; W Jackson Hall; Torsten Kayser; Helmut Klein; Brian Olshansky; Keith A Power; David Wilber; Wojciech Zareba; Arthur J Moss
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-07       Impact factor: 1.468

3.  Long-term incidence of inappropriate shocks in patients with implantable cardioverter defibrillators in clinical practice-an underestimated complication?

Authors:  Daniel Hofer; Jan Steffel; David Hürlimann; Laurent Haegeli; Thomas F Lüscher; Firat Duru; Urs Eriksson; Nazmi Krasniqi
Journal:  J Interv Card Electrophysiol       Date:  2017-11-25       Impact factor: 1.900

Review 4.  [Home Monitoring with implantable ICD--a diagnostic innovation?].

Authors:  W Jung; R Birkemeyer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-09

Review 5.  The role of remote monitoring in the reduction of inappropriate implantable cardioverter defibrillator therapies.

Authors:  J C J Res; D A M J Theuns; L Jordaens
Journal:  Clin Res Cardiol       Date:  2006       Impact factor: 5.460

6.  Relevance of Monitoring Atrial Fibrillation in Clinical Practice.

Authors:  Thorsten Lewalter; Giuseppe Boriani
Journal:  Arrhythm Electrophysiol Rev       Date:  2012-09

7.  Low rate of and rapid attention to inappropriate ICD shocks with remote device and rhythm monitoring: a qualitative study.

Authors:  Emma Sandgren; Cecilia Rorsman; Johan Engdahl; Nils Edvardsson
Journal:  Open Heart       Date:  2015-07-27