Literature DB >> 1564220

Dobutamine stress echocardiography: correlation with coronary lesion severity as determined by quantitative angiography.

D S Segar1, S E Brown, S G Sawada, T Ryan, H Feigenbaum.   

Abstract

This study was performed 1) to determine the ability of dobutamine stress echocardiography to detect stenoses in individual coronary arteries by utilizing a new model of coronary artery distribution; 2) to evaluate its ability to detect coronary artery stenosis with a minimal lumen diameter less than 1 mm; and 3) to correlate the heart rate at which a positive test result occurs with the severity of coronary artery disease. Eighty-five patients were identified who underwent both dobutamine stress echocardiography and quantitative coronary angiography. During incremental infusion of dobutamine, two-dimensional echocardiograms were obtained at rest, during low and peak stress and after stress. Echocardiograms were interpreted with use of a modified 16-segment model with an anteroinferior overlap scheme. The overall sensitivity of the technique for the detection of significant coronary artery disease (diameter stenosis greater than or equal to 50%) was 95%; specificity was 82% and accuracy 92%. The sensitivity for detection of individual coronary artery lesions did not differ significantly (p greater than 0.05) in the three major coronary artery distributions (79% left anterior descending, 70% left circumflex, 77% right coronary artery). Among 35 stenoses with a minimal lumen diameter less than 1 mm, the test result was positive in 30 (86%). Test results were correctly positive for 88%, 82% and 86% of stenoses in the left anterior descending, left circumflex and right coronary artery distributions, respectively. Multivessel disease was present in 11 of 16 patients with normal wall motion at rest who developed a wall motion abnormality at a heart rate less than 125 beats/min. The incidence of multivessel disease was statistically higher in patients with positive findings on a dobutamine stress echocardiogram at a heart rate less than or equal to 125/min. In conclusion, dobutamine stress echocardiography has high sensitivity and specificity for the detection and localization of coronary artery disease. Detection of stenosis in individual coronary arteries is improved in those lesions with a minimal lumen diameter less than 1 mm. Patients with a positive test result at a heart rate less than or equal to 125 beats/min have a high likelihood of multivessel coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1564220     DOI: 10.1016/0735-1097(92)90324-g

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  43 in total

1.  Noninvasive Cardiac Imaging in Chest Pain Syndromes.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1998-11       Impact factor: 2.300

2.  Hibernating myocardium in post-ischaemic heart failure: pathophysiology, identification and revascularisation.

Authors:  D Pagano
Journal:  Ann R Coll Surg Engl       Date:  2000-07       Impact factor: 1.891

3.  Usefulness of distinct activity thresholds according to baseline regional asynergy for predicting functional recovery in patients with chronic coronary artery disease and left ventricular dysfunction: a study with nitrate-enhanced sestamibi gated SPECT.

Authors:  M Leoncini; G Marcucci; R Sciagrà; F Frascarelli; F Bellandi; M Gallopin; A Mennuti; R P Dabizzi
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

4.  A meta-analytic comparison of echocardiographic stressors.

Authors:  Yoshinori Noguchi; Shizuko Nagata-Kobayashi; James E Stahl; John B Wong
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

Review 5.  Stress echocardiography for the detection and assessment of coronary artery disease.

Authors:  Nowell M Fine; Patricia A Pellikka
Journal:  J Nucl Cardiol       Date:  2011-05       Impact factor: 5.952

Review 6.  Myocardial perfusion imaging versus two-dimensional echocardiography: comparative value in the diagnosis of coronary artery disease.

Authors:  M S Verani
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

Review 7.  The role of stress echocardiography versus stress perfusion: a view from the other side.

Authors:  F A Chaudhry
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

8.  Low-dose dobutamine nitrate-enhanced technetium 99m sestamibi gated SPECT versus low-dose dobutamine echocardiography for detecting reversible dysfunction in ischemic cardiomyopathy.

Authors:  Mario Leoncini; Roberto Sciagrà; Francesco Bellandi; Mauro Maioli; Stelvio Sestini; Gabriella Marcucci; Angela Coppola; Fabio Frascarelli; Alberto Mennuti; Roberto P Dabizzi
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

9.  A comparison of dobutamine and maximal exercise as stress for thallium scintigraphy.

Authors:  D R Wallbridge; A C Tweddel; W Martin; I Hutton
Journal:  Eur J Nucl Med       Date:  1993-04

Review 10.  Stress echocardiogaphy: a useful test for assessing cardiac risk in diabetes.

Authors:  Rajan Sharma; Denis Pellerin
Journal:  Vasc Health Risk Manag       Date:  2009-04-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.