The effect of wave reflection and refraction at soft tissue interfaces during ultrasound hyperthermia treatments.

X Fan1, K Hynynen.   

Abstract

An improved numerical model for calculating the ultrasonic power deposition in layered medium was developed and experimentally tested. The new model takes into account the ultrasound wave reflection and refraction at the tissue interfaces thereby providing improved accuracy in ultrasound hyperthermia treatment planning. The model was compared with a simplified model to evaluate when the tissue interfaces could be ignored in the hyperthermia treatment planning and evaluation. The effect of variations in water and tissue temperatures, the fat layer thicknesses, and the beam entrance angle were also investigated to establish guidelines for treatment execution. It was found that in most cases the effects of the soft tissue interfaces can be ignored. However, in some instances the acoustic focus may be shifted several millimeters off axis in layered medium. This is important when sharply focused transducers are used for ultrasound surgery or under the condition of pulsed, high-temperature hyperthermia treatments.

Entities:  

Mesh:

Year:  1992        PMID: 1564208     DOI: 10.1121/1.402452

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  5 in total

1.  The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study.

Authors:  Daniel Pajek; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

2.  Refraction correction in 3D transcranial ultrasound imaging.

Authors:  Brooks D Lindsey; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2014-01       Impact factor: 1.578

3.  A High-Frequency Phased Array System for Transcranial Ultrasound Delivery in Small Animals.

Authors:  Saba Rahimi; Ryan Matthew Jones; Kullervo Hynynen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

4.  Safety limitations of MR-HIFU treatment near interfaces: a phantom validation.

Authors:  Elizabeth Hipp; Ari Partanen; Gregory S Karczmar; Xiaobing Fan
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

5.  The Correction of Focal Point Displacement Caused by the Refraction of the Beams in High-Intensity Focused Ultrasound.

Authors:  Mohammad Rezaei; Karim Khoshgard; Mehdi Mousavi
Journal:  J Med Signals Sens       Date:  2017 Jul-Sep
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.