Literature DB >> 15640636

Prolonged isoflurane sedation of intensive care unit patients with the Anesthetic Conserving Device.

Peter V Sackey1, Claes-Roland Martling, Fredrik Granath, Peter J Radell.   

Abstract

OBJECTIVE: To test the efficacy and patient safety of a new method for administering isoflurane for prolonged sedation in the intensive care unit.
DESIGN: Randomized controlled trial.
SETTING: Multidisciplinary university intensive care unit, January 2002 to July 2003. PATIENTS: Forty ventilator-dependent intensive care unit patients 18-80 yrs old, expected to need >12 hrs sedation.
INTERVENTIONS: Patients were randomized to sedation with inhaled isoflurane via the Anesthetic Conserving Device or intravenous midazolam infusion. Study duration was 96 hrs or until extubation.
MEASUREMENTS AND MAIN RESULTS: Primary end points were wake-up times from termination of sedative administration and proportion of time within a predefined desired interval on a sedation scale (Bloomsbury Sedation Score). Practical and patient-related complications with the Anesthetic Conserving Device were noted. Hemodynamic, hepatic, and renal side effects were monitored. Wake-up times were significantly shorter in the isoflurane group than in the control group (time to extubation [mean +/- sd] 10 +/- 5 vs. 252 +/- 271 mins, time to follow verbal command 10 +/- 8 vs. 110 +/- 132 mins). Proportion of time within the desired sedation interval was comparable between groups (isoflurane 54%, midazolam 59% of sedation time). Few minor practical problems with this new method for isoflurane administration were noted. No serious complications related to either sedative drug occurred. We found no hemodynamic, hepatic, or renal adverse effects related to either sedative protocol.
CONCLUSIONS: Isoflurane via the Anesthetic Conserving Device is a safe and efficacious method for sedation in the intensive care unit, with short wake-up times after termination of administration. The Anesthetic Conserving Device allows easily titratable administration of isoflurane without costly equipment and can be safely managed by nursing staff.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15640636     DOI: 10.1097/01.ccm.0000145951.76082.77

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  47 in total

1.  Evaluating the efficiency of desflurane reflection in two commercially available reflectors.

Authors:  Hagen Bomberg; Marcel Wessendorf; Martin Bellgardt; Max Veddeler; Stefan Wagenpfeil; Thomas Volk; Heinrich V Groesdonk; Andreas Meiser
Journal:  J Clin Monit Comput       Date:  2016-07-08       Impact factor: 2.502

Review 2.  Evolving targets for sedation during mechanical ventilation.

Authors:  Steven D Pearson; Bhakti K Patel
Journal:  Curr Opin Crit Care       Date:  2020-02       Impact factor: 3.687

3.  [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation].

Authors:  A Meiser; M Bellgardt; H Vogelsang; C Sirtl; T Weber
Journal:  Anaesthesist       Date:  2010-11       Impact factor: 1.041

Review 4.  [Burn trauma--Part 2. Anesthesiological, surgical and intensive care management].

Authors:  G A Giessler; T Mayer; T Trupkovic
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

5.  [Sedation concepts with volatile anaesthetics in intensive care: practical use and current experiences with the AnaConDa system].

Authors:  J Kompardt; K Schärff; K Kubosch; C Pohl; M Bomplitz; J Soukup
Journal:  Anaesthesist       Date:  2008-12       Impact factor: 1.041

6.  Volatile agents for ICU sedation?

Authors:  David Bracco; Francesco Donatelli
Journal:  Intensive Care Med       Date:  2011-03-29       Impact factor: 17.440

7.  Short-term evaluation of sedation with sevoflurane administered by the anesthetic conserving device in critically ill patients.

Authors:  Maurizio Migliari; Giacomo Bellani; Roberto Rona; Stefano Isgrò; Beatrice Vergnano; Tommaso Mauri; Nicolò Patroniti; Antonio Pesenti; Giuseppe Foti
Journal:  Intensive Care Med       Date:  2009-02-03       Impact factor: 17.440

8.  Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevoflurane.

Authors:  Andreas Meiser; Martin Bellgardt; Javier Belda; Kerstin Röhm; Heinz Laubenthal; Clemens Sirtl
Journal:  J Clin Monit Comput       Date:  2009-02-03       Impact factor: 2.502

9.  Evidence and consensus-based German guidelines for the management of analgesia, sedation and delirium in intensive care--short version.

Authors:  Jörg Martin; Anja Heymann; Katrin Bäsell; Ralf Baron; Rolf Biniek; Hartmut Bürkle; Peter Dall; Christine Dictus; Verena Eggers; Ingolf Eichler; Lothar Engelmann; Lars Garten; Wolfgang Hartl; Ulrike Haase; Ralf Huth; Paul Kessler; Stefan Kleinschmidt; Wolfgang Koppert; Franz-Josef Kretz; Heinz Laubenthal; Guenter Marggraf; Andreas Meiser; Edmund Neugebauer; Ulrike Neuhaus; Christian Putensen; Michael Quintel; Alexander Reske; Bernard Roth; Jens Scholz; Stefan Schröder; Dierk Schreiter; Jürgen Schüttler; Gerhard Schwarzmann; Robert Stingele; Peter Tonner; Philip Tränkle; Rolf Detlef Treede; Tomislav Trupkovic; Michael Tryba; Frank Wappler; Christian Waydhas; Claudia Spies
Journal:  Ger Med Sci       Date:  2010-02-02

Review 10.  The incidence of sub-optimal sedation in the ICU: a systematic review.

Authors:  Daniel L Jackson; Clare W Proudfoot; Kimberley F Cann; Tim S Walsh
Journal:  Crit Care       Date:  2009-12-16       Impact factor: 9.097

View more