Literature DB >> 15640407

Insulin, C-peptide, and restenosis after femoral artery balloon angioplasty in type II diabetic and nondiabetic patients.

Thomas Maca1, Martin Schillinger, Ahmad Hamwi, Wolfgang Mlekusch, Schila Sabeti, Oswald Wagner, Erich Minar.   

Abstract

PURPOSE: Endogenous and exogenous insulin is suggested to stimulate hypertrophic wound-healing responses and therefore may promote neointimal hyperplasia and restenosis after balloon angioplasty. The ratio of C-peptide to insulin reflects endogenous insulin secretion. In diabetic patients with insulin substitution, lower ratios display a higher proportion of exogenous insulin. The association and interaction of insulin and C-peptide with restenosis after percutaneous transluminal angioplasty (PTA) was investigated in type II diabetic and nondiabetic patients.
MATERIALS AND METHODS: The study group included 76 patients (median age, 68 years; interquartile range [IQR], 58-74 years; 55 men [72%]; 31 patients [41%] with type II diabetes) with intermittent claudication (n = 49; 64%) or critical limb ischemia (n = 27; 36%) who underwent primary successful femoral PTA. C-peptide and insulin levels were measured at baseline, and patients were followed to determine restenosis (> or =50%) at 12 months by color-coded duplex sonography.
RESULTS: Restenosis was found in 34 patients (45%) at 12 months. Patients with restenosis had higher insulin levels (median, 21.3 microU/mL IQR, 11.3-35.5 microU/mL) and a lower C-peptide/insulin ratio (median, 16; IQR, 10-21) compared with patients without restenosis (median insulin level, 11.6 microU/mL; IQR, 9.1-22.0 microU/mL [P = .008]; median ratio, 19 [IQR, 17-25], P = .039). In nondiabetic patients, insulin levels were significantly associated with restenosis (P = .046), whereas the ratio of C-peptide to insulin showed no association with restenosis. In patients with type II diabetes (n = 31; 41%), in contrast, the C-peptide/insulin ratio was associated with restenosis (P = .047), whereas insulin levels showed no significant association with restenosis (P = .14).
CONCLUSIONS: Insulin levels and the C-peptide/insulin ratio were associated with restenosis after femoral PTA. Exogenous and endogenous insulin may play a role in the pathogenesis of recurrent lumen loss after balloon angioplasty.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15640407     DOI: 10.1097/01.RVI.0000136030.26074.33

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  4 in total

1.  Stenting for superficial femoral artery atherosclerotic occlusion: long-term follow-up results.

Authors:  Yoshio Sasaki; Myung-Woo Hwang; Kuniyuki Shirasawa; Shinichi Takeda; Hiroyuki Ayukawa; Katsura Inenaga-Kitaura; Rei Takeoka; Yasushi Kitaura; Chuichi Kawai
Journal:  Heart Vessels       Date:  2008-07-23       Impact factor: 2.037

Review 2.  Percutaneous treatment of peripheral vascular disease: the role of diabetes and inflammation.

Authors:  Louis L Nguyen
Journal:  J Vasc Surg       Date:  2007-06       Impact factor: 4.268

3.  In-hospital daily insulin dose predicts long-term adverse outcome in patients with diabetes with ST-elevation myocardial infarction treated with successful primary percutaneous angioplasty.

Authors:  Tomasz Jeżewski; Jan Z Peruga; Jarosław D Kasprzak; Tomasz Bendinger; Michal Plewka; Jarosław Drożdż; Józef Drzewoski; Maria Krzeminska-Pakula
Journal:  Arch Med Sci       Date:  2014-10-23       Impact factor: 3.318

4.  Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine.

Authors:  Qi Zhang; Lin Lu; LiJin Pu; RuiYan Zhang; Jie Shen; ZhengBing Zhu; Jian Hu; ZhenKun Yang; QiuJin Chen; WeiFeng Shen
Journal:  Cardiovasc Diabetol       Date:  2007-06-05       Impact factor: 9.951

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.