Literature DB >> 15640384

Ultrasound: a reproducible method to measure conduit vein compliance.

Patricia C E de Groot1, Michiel W P Bleeker, Maria T E Hopman.   

Abstract

Classical venous occlusion plethysmography (VOP) of the leg, often used to assess venous compliance, measures properties of the whole calf, including volume changes at the arterial side and the interstitial fluid accumulation that occurs as a result of the enhanced capillary pressure during venous occlusion. We present an ultrasound technique to measure the compliance of one major conduit vein in the leg. Ultrasound measurements of the popliteal vein were compared with classical VOP measurements, which were performed simultaneously in one subject. Six healthy individuals were measured on three occasions to assess short- and long-term reproducibility of the measurements. Six motor complete spinal cord-injured (SCI) individuals were included to compare venous compliance in subjects with known pathological changes of the venous system with controls. The ultrasound and VOP measurements of venous compliance correlated significantly (r(2) = 0.39, P = 0.001). Ultrasound provides reproducible measurements with short- and long-term coefficients of variation ranging from 10 to 15% for popliteal vein compliance and from 2 to 9% for absolute diameters at the different venous pressure steps. In addition, by using ultrasound, we were able to detect an 80% reduction in the compliance of the popliteal vein in SCI individuals compared with controls (P < 0.01). In conclusion, ultrasound is a suitable and reproducible method to measure conduit vein compliance and provides the possibility to specifically assess compliance of one vein instead of the whole calf.

Entities:  

Mesh:

Year:  2005        PMID: 15640384     DOI: 10.1152/japplphysiol.01166.2004

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  9 in total

1.  The effect of bed rest and an exercise countermeasure on leg venous function.

Authors:  Noortje T L van Duijnhoven; Michiel W P Bleeker; Patricia C E de Groot; Dick H J Thijssen; Dieter Felsenberg; Jörn Rittweger; Maria T E Hopman
Journal:  Eur J Appl Physiol       Date:  2008-08-22       Impact factor: 3.078

2.  Artificial gravity with ergometric exercise can prevent enhancement of popliteal vein compliance due to 4-day head-down bed rest.

Authors:  Yong-Jie Yao; Yong-Sheng Zhu; Chang-Bin Yang; Xiao-Dong Zhou; Xi-Qing Sun
Journal:  Eur J Appl Physiol       Date:  2011-07-24       Impact factor: 3.078

3.  Efficacy of micromobile foot compression device in increasing lower limb venous blood flow.

Authors:  Thomas Charles; Stephen Mackintosh; James Fingleton; Irene Braithwaite; Mark Weatherall; Richard Beasley
Journal:  Int J Vasc Med       Date:  2013-11-11

4.  Venous haemodynamics of Jet Impulse Technology within a lower limb fibreglass cast: a randomized controlled trial.

Authors:  Irene Braithwaite; Stephen Mackintosh; Samantha Buchanan; Kerstin Schwarzenlander; Bernadette De Ruyter
Journal:  JRSM Open       Date:  2017-01-01

Review 5.  Assessment of Phasic Changes of Vascular Size by Automated Edge Tracking-State of the Art and Clinical Perspectives.

Authors:  Luca Mesin; Stefano Albani; Piero Policastro; Paolo Pasquero; Massimo Porta; Chiara Melchiorri; Gianluca Leonardi; Carlo Albera; Paolo Scacciatella; Pierpaolo Pellicori; Davide Stolfo; Andrea Grillo; Bruno Fabris; Roberto Bini; Alberto Giannoni; Antonio Pepe; Leonardo Ermini; Stefano Seddone; Gianfranco Sinagra; Francesco Antonini-Canterin; Silvestro Roatta
Journal:  Front Cardiovasc Med       Date:  2022-01-21

6.  Evidence that large vessels do affect near infrared spectroscopy.

Authors:  Stefano Seddone; Leonardo Ermini; Piero Policastro; Luca Mesin; Silvestro Roatta
Journal:  Sci Rep       Date:  2022-02-09       Impact factor: 4.379

7.  Tendon vibration attenuates superficial venous vessel response of the resting limb during static arm exercise.

Authors:  Anna Ooue; Kohei Sato; Ai Hirasawa; Tomoko Sadamoto
Journal:  J Physiol Anthropol       Date:  2012-11-07       Impact factor: 2.867

8.  Decreased compliance in the deep and superficial conduit veins of the upper arm during prolonged cycling exercise.

Authors:  Anna Oue; Kohei Sato; Marina Yoneya; Tomoko Sadamoto
Journal:  Physiol Rep       Date:  2017-04

9.  Compliance in the deep and superficial conduit veins of the nonexercising arm is unaffected by short-term exercise.

Authors:  Anna Oue; Tomoko Sadamoto
Journal:  Physiol Rep       Date:  2018-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.