| Literature DB >> 15639461 |
Robin E Choo1, Constance M Murphy, Hendrée E Jones, Marilyn A Huestis.
Abstract
This paper details a validated liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI-MS/MS) method for the quantification of methadone, and its metabolites 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), 2-ethyl-5-methyl-3,3-diphenylpyraline (EMDP) and methadol in human meconium. Limits of detection (LOD) were determined to be 1.0 ng/g for methadone, EDDP and EMDP and 2.5 ng/g for methadol. The limits of quantitation (LOQ) for methadone, EDDP, EMDP were 5 and 25 ng/g for methadol. Linearity ranged from 5.0 to 500 ng/g. Following solid-phase extraction, no matrix effect was observed. This method proved to be suitable for the quantification of methadone, EDDP and EMDP and the semi-quantitation of methadol in meconium. Literature review revealed no other published LC-APCI-MS/MS method for the detection of methadone and its three main metabolites in meconium specimens.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15639461 DOI: 10.1016/j.jchromb.2004.10.068
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205