Literature DB >> 15635829

A study on the clinical usefulness of digitalized random-dot stereoacuity test.

Jae Wook Yang1, Min Ho Son, Il Han Yun.   

Abstract

Existing methods of stereoacuity testing need specific glasses or optical device for use. We have designed a new stereoacuity test for the digitalized, random-dot stereogram and researched its clinical usefulness. A digitalized, random-dot, stereoacuity test card was created with a computer program that used a preferred symbol and the designed system was tested along with the Randot preschool stereoacuity, Titmus-fly and Lang tests to compare their sensitivity and specificity. The mean success rate of the digitalized, random-dot test was 98.2%, while the rates of the Randot preschool stereoacuity, Titmus-fly and Lang tests were 89.3%, 74.2% and 86.1%, respectively. Sensitivity and specificity of the new test were 100% and 95.3%, respectively, which were not that different from those of the Randot preschool stereoacuity, Titmus-fly and Lang tests. We found that the digitalized, random-dot, stereoacuity test has a high success rate and can be appropriately used in medical examinations and follow-up tests for strabismus patients.

Entities:  

Mesh:

Year:  2004        PMID: 15635829     DOI: 10.3341/kjo.2004.18.2.154

Source DB:  PubMed          Journal:  Korean J Ophthalmol        ISSN: 1011-8942


  5 in total

1.  Characterizing the Randot Preschool stereotest: Testability, norms, reliability, specificity and sensitivity in children aged 2-11 years.

Authors:  Jenny C A Read; Sheima Rafiq; Jess Hugill; Therese Casanova; Carla Black; Adam O'Neill; Vicente Puyat; Helen Haggerty; Kathryn Smart; Christine Powell; Kate Taylor; Michael P Clarke; Kathleen Vancleef
Journal:  PLoS One       Date:  2019-11-07       Impact factor: 3.240

2.  Effect of chromatic contrast on stereoacuity measurement with computer-aided three-dimensional technology.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  Ann Transl Med       Date:  2019-05

3.  Evaluating stereoacuity with 3D shutter glasses technology.

Authors:  Huang Wu; Han Jin; Ying Sun; Yang Wang; Min Ge; Yang Chen; Yunfeng Chi
Journal:  BMC Ophthalmol       Date:  2016-04-26       Impact factor: 2.209

4.  Screening for Stereopsis of Children Using an Autostereoscopic Smartphone.

Authors:  Yanhui Yang; Huang Wu
Journal:  J Ophthalmol       Date:  2019-10-31       Impact factor: 1.909

5.  Quantifying Suppression in Anisometropic Amblyopia With VTS4 (Vision Therapy System 4).

Authors:  Shivalika Sehgal; PremNandhini Satgunam
Journal:  Transl Vis Sci Technol       Date:  2020-11-19       Impact factor: 3.283

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.