Literature DB >> 15634302

Precision of fit and clinical evaluation of all-ceramic full restorations followed between 0.5 and 5 years.

I Naert1, A Van der Donck, L Beckers.   

Abstract

Currently CAD-CAM systems are rapidly gaining importance in dental practice as some of their products aim to combine aesthetics with strength and are free of metals. This study reports on the crown adaptation, marginal fit and clinical behaviour of 300 all-ceramic full coverage restorations (Procera, Gothenburg, Sweden) placed in one clinical centre and followed up to 5 years. The marginal fit and coping adaptation before and after luting was determined by direct measurement as well as after sectioning in a laboratory study. Three hundred all-ceram restorations were installed in 165 patients between 1994 and 1998. Before the end of 2000, patients were recalled to assess their restorations, using the California Dental Association quality evaluation index, their own appreciation, as well as the reaction towards the periodontium. The in vitro data revealed a mean marginal adaptation of 30 microm, before and after luting of the Al(2)0(3)-coping onto the tooth. However, at the deepest part of the chamfer, the distance increased to 135 microm. In the clinical study only one restoration fractured, while in 6% small porcelain infractions occurred. After polishing the latter, no persistent patient complaints remained. At the last recall visit 1.8% of the margins were rated unacceptable. Dentists rated 72 and 78% of the restorations excellent for surface, colour and anatomic form respectively. Eighty-seven per cent of the patients rated their restorations more than 7/10 on an ordered analogue scale for aesthetics as well as for function.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15634302     DOI: 10.1111/j.1365-2842.2004.01374.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  8 in total

1.  Clinical results of lithium-disilicate crowns after up to 9 years of service.

Authors:  Maren Gehrt; Stefan Wolfart; Nicole Rafai; Sven Reich; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-03-07       Impact factor: 3.573

2.  [Clinical pathway and preparation method of high-precision tooth shoulder platform].

Authors:  Tian Luo; Jun-Ying Li; Hai-Yang Yu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-12-01

3.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

4.  Evaluation of marginal fit of two all-ceramic copings with two finish lines.

Authors:  Gulce Subasi; Nilgun Ozturk; Ozgur Inan; Nalan Bozogullari
Journal:  Eur J Dent       Date:  2012-04

5.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

6.  Marginal Discrepancy of Cast Copings to Abutments with Three Different Luting Agents.

Authors:  José Rosas; Frank Mayta-Tovalino; Maria Eugenia Guerrero; Pedro Luis Tinedo-López; Claudia Delgado; Vanessa Z Ccahuana-Vasquez
Journal:  Int J Dent       Date:  2019-09-02

7.  CAD/CAM Zirconia vs. slip-cast glass-infiltrated Alumina/Zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial.

Authors:  Murat Cavit Cehreli; Ali Murat Kökat; Kivanç Akça
Journal:  J Appl Oral Sci       Date:  2009 Jan-Feb       Impact factor: 2.698

8.  Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations.

Authors:  Roberto Padrós; Luís Giner; Mariano Herrero-Climent; Carlos Falcao-Costa; José-Vicente Ríos-Santos; Francisco Javier Gil
Journal:  Int J Environ Res Public Health       Date:  2020-06-15       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.