Literature DB >> 1563224

Electrical impedance tomography with cortical or scalp electrodes during global cerebral ischaemia in the anaesthetised rat.

D S Holder1.   

Abstract

The performance of a prototype impedance imaging (Electrical Impedance Tomography, EIT) system using cortical or scalp electrodes has been assessed in a model of global cerebral ischaemia in the anaesthetised rat. In preliminary calibration experiments using a circular array of electrodes around a tank of saline, the centre of a polythene rod could be localised with a mean error of 4% of the tank diameter, and two such rods could be discriminated when separated by 22% of the tank diameter. Cerebral ischaemia was produced by diathermy of the vertebral arteries and reversible occlusion of the common carotid arteries for 15 min. A bimodal impedance increase of about 50-200% was recorded with a ring of cortical electrodes in the fronto-occipital plane. With a similarly oriented ring of scalp electrodes, a unimodal impedance increase of about 10% was observed. In both cases, impedance reversed after cerebral reperfusion. Similar but irreversible changes were observed post mortem. As the reconstruction algorithm assumes constant initial resistivity, this suggests that modifications to allow for initial conditions would be needed for more accurate imaging with scalp electrodes.

Entities:  

Mesh:

Year:  1992        PMID: 1563224     DOI: 10.1088/0143-0815/13/1/008

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  5 in total

Review 1.  Electrical impedance tomography (EIT) of brain function.

Authors:  D S Holder
Journal:  Brain Topogr       Date:  1992       Impact factor: 3.020

2.  Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging.

Authors:  H R Gamba; D T Delpy
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

3.  The Physiological Society proceedings of the scientific meeting held at University College London, 16-18 April 1996. Abstracts.

Authors: 
Journal:  J Physiol       Date:  1996-07       Impact factor: 5.182

4.  Equivalent dipole source localization of EEG and evoked potentials: sources of errors or sources with confidence?

Authors:  B W van Dijk; H Spekreijse; T Yamazaki
Journal:  Brain Topogr       Date:  1993       Impact factor: 3.020

5.  A method for recording resistance changes non-invasively during neuronal depolarization with a view to imaging brain activity with electrical impedance tomography.

Authors:  Ori Gilad; Anthony Ghosh; Dongin Oh; David S Holder
Journal:  J Neurosci Methods       Date:  2009-03-26       Impact factor: 2.390

  5 in total