Literature DB >> 15627960

Liquid ultraviolet matrix-assisted laser desorption/ionization -- mass spectrometry for automated proteomic analysis.

Rainer Cramer1, Steve Corless.   

Abstract

We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15627960     DOI: 10.1002/pmic.200400956

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  4 in total

1.  Analysis of native milk oligosaccharides directly from thin-layer chromatography plates by matrix-assisted laser desorption/ionization orthogonal-time-of-flight mass spectrometry with a glycerol matrix.

Authors:  Klaus Dreisewerd; Stefanie Kölbl; Jasna Peter-Katalinić; Stefan Berkenkamp; Gottfried Pohlentz
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-10       Impact factor: 3.109

2.  Liquid matrix deposition on conductive hydrophobic surfaces for tuning and quantitation in UV-MALDI mass spectrometry.

Authors:  Magnus Palmblad; Rainer Cramer
Journal:  J Am Soc Mass Spectrom       Date:  2007-01-16       Impact factor: 3.109

3.  Production and analysis of multiply charged negative ions by liquid atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Oliver J Hale; Pavel Ryumin; Jeffery M Brown; Michael Morris; Rainer Cramer
Journal:  Rapid Commun Mass Spectrom       Date:  2018-09-12       Impact factor: 2.419

4.  Liquid AP-UV-MALDI enables stable ion yields of multiply charged peptide and protein ions for sensitive analysis by mass spectrometry.

Authors:  Rainer Cramer; Alexander Pirkl; Franz Hillenkamp; Klaus Dreisewerd
Journal:  Angew Chem Int Ed Engl       Date:  2013-01-22       Impact factor: 15.336

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.