Ultrasound system to measure esophageal varix pressure: an in vitro validation study.

James L Puckett1, Jianmin Liu, Vikas Bhalla, David Kravetz, Mary Lee Krinsky, Tarek Hassanein, Ravinder K Mittal.   

Abstract

We report our experience with an ultrasound system to measure esophageal varix pressure in an in vitro model. The ultrasound system consists of a 12.5 MHz frequency intraluminal ultrasound probe, a water infusion catheter, and a manometry catheter, all contained within a nondistensible latex bag. Esophagi and external jugular veins were harvested from five pigs. The vein and ultrasound system were placed inside the esophagus. One end of the vein was connected to a water reservoir to modulate its pressure; the other end was connected in two different ways to simulate hydrodynamic and hydrostatic flow conditions. The bag was inflated with water until vein occlusion was discernible on the ultrasound images. The influences of vein pressure, vein cross-sectional area and esophageal elasticity on the ultrasound measurement of vein pressure were assessed. A total of 108 trials were performed at nine different vein pressures. Complete vein occlusion occurred when the bag pressure was slightly greater (1.4 +/- 0.7 mmHg) than the vein pressure. For a vein pressure of 25 mmHg, the average occlusion and opening pressures were 27 +/- 0.2 and 25.7 +/- 0.3 mmHg, respectively (P < .05) suggesting that the vein opening pressure on the ultrasound images is more accurate than the vein closing pressure. In conclusion, the ultrasound technique can accurately measure intravariceal pressure in vitro. The bag pressure at the point of vein reopening is the best determinant of the vein pressure.

Entities:  

Mesh:

Year:  2004        PMID: 15626729     DOI: 10.1152/ajpgi.00373.2004

Source DB:  PubMed          Journal:  Am J Physiol Gastrointest Liver Physiol        ISSN: 0193-1857            Impact factor:   4.052


  3 in total

1.  Effects of propranolol or propranolol plus isosorbide-5-mononitrate on variceal pressure in schistosomiasis.

Authors:  De-Run Kong; Chao Ma; Min Wang; Jing-Guang Wang; Chen Chen; Lei Zhang; Jia-Hu Hao; Pan Li; Jian-Ming Xu
Journal:  World J Gastroenterol       Date:  2013-07-14       Impact factor: 5.742

2.  A novel fiber-optic pressure sensor device for measuring variceal pressure.

Authors:  Xi Wang; Huixian Li; Jing Wang; Aijiu Wu; Derun Kong
Journal:  Exp Ther Med       Date:  2019-10-01       Impact factor: 2.447

3.  Validation of an Endoscopic Fibre-Optic Pressure Sensor for Noninvasive Measurement of Variceal Pressure.

Authors:  Bin Sun; De-Run Kong; Su-Wen Li; Dong-Feng Yu; Ging-Jing Wang; Fang-Fang Yu; Qiong Wu; Jian-Ming Xu
Journal:  Biomed Res Int       Date:  2016-05-23       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.