Literature DB >> 15626625

A high density microelectrode array biosensor for detection of E. coli O157:H7.

Stephen M Radke1, Evangelyn C Alocilja.   

Abstract

A high density microelectrode array biosensor was developed for the detection of Escherichia coli O157:H7. The biosensor was fabricated from (100) silicon with a 2 microm layer of thermal oxide as an insulating layer, an active area of 9.6 mm2 and consists of an interdigitated gold electrode array. The sensor surface was functionalised for bacterial detection using heterobifunctional crosslinkers and immobilised polyclonal antibodies to create a biological sensing surface. Bacteria suspended in solution became attached to the immobilised antibodies when the biosensor was tested in liquid samples. The change in impedance caused by the bacteria was measured over a frequency range of 100 Hz-10 M Hz. The biosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The biosensor was able to discriminate between cellular concentrations of 10(4)-10(7)CFU/mL and has applications in detecting pathogens in food samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15626625     DOI: 10.1016/j.bios.2004.07.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  31 in total

Review 1.  New tools and new biology: recent miniaturized systems for molecular and cellular biology.

Authors:  Morgan Hamon; Jong Wook Hong
Journal:  Mol Cells       Date:  2013-12-02       Impact factor: 5.034

2.  A novel and highly specific phage endolysin cell wall binding domain for detection of Bacillus cereus.

Authors:  Minsuk Kong; Jieun Sim; Taejoon Kang; Hoang Hiep Nguyen; Hyun Kyu Park; Bong Hyun Chung; Sangryeol Ryu
Journal:  Eur Biophys J       Date:  2015-06-05       Impact factor: 1.733

Review 3.  Electrochemical biosensors for pathogen detection.

Authors:  Ellen Cesewski; Blake N Johnson
Journal:  Biosens Bioelectron       Date:  2020-04-12       Impact factor: 10.618

4.  Improvement in cell capture throughput using parallel bioactivated microfluidic channels.

Authors:  Mehdi Javanmard; Farbod Babrzadeh; Pål Nyrén; Ronald W Davis
Journal:  Biomed Microdevices       Date:  2012-08       Impact factor: 2.838

5.  Continuous size-based separation of microparticles in a microchannel with symmetric sharp corner structures.

Authors:  Liang-Liang Fan; Xu-Kun He; Yu Han; Li Du; Liang Zhao; Jiang Zhe
Journal:  Biomicrofluidics       Date:  2014-04-02       Impact factor: 2.800

6.  Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Biosens Bioelectron       Date:  2010-03-18       Impact factor: 10.618

7.  Detection of single tumor cell resistance with aptamer biochip.

Authors:  Lixue Wang; Qin Zheng; Quan'an Zhang; Hanfeng Xu; Jinlong Tong; Chuandong Zhu; Yuan Wan
Journal:  Oncol Lett       Date:  2012-08-31       Impact factor: 2.967

8.  An aptamer-based biosensor for colorimetric detection of Escherichia coli O157:H7.

Authors:  Wenhe Wu; Jie Zhang; Meiqin Zheng; Yuhong Zhong; Jie Yang; Yuhong Zhao; Wenping Wu; Wei Ye; Jie Wen; Qi Wang; Jianxin Lu
Journal:  PLoS One       Date:  2012-11-07       Impact factor: 3.240

9.  Nucleic Acid-based Detection of Bacterial Pathogens Using Integrated Microfluidic Platform Systems.

Authors:  Clarissa Lui; Nathaniel C Cady; Carl A Batt
Journal:  Sensors (Basel)       Date:  2009-05-18       Impact factor: 3.576

10.  Aptasensors for rapid detection of Escherichia coli O157:H7 and Salmonella typhimurium.

Authors:  Wen-He Wu; Min Li; Yue Wang; Hou-Xian Ouyang; Lin Wang; Ci-Xiu Li; Yu-Chen Cao; Qing-He Meng; Jian-Xin Lu
Journal:  Nanoscale Res Lett       Date:  2012-11-29       Impact factor: 4.703

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.