Literature DB >> 15626601

Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.

Yasutaka Matsubara1, Kagan Kerman, Masaaki Kobayashi, Shouhei Yamamura, Yasutaka Morita, Eiichi Tamiya.   

Abstract

A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15626601     DOI: 10.1016/j.bios.2004.07.002

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  12 in total

Review 1.  Sample pretreatment and nucleic acid-based detection for fast diagnosis utilizing microfluidic systems.

Authors:  Jung-Hao Wang; Chih-Hung Wang; Gwo-Bin Lee
Journal:  Ann Biomed Eng       Date:  2011-12-07       Impact factor: 3.934

2.  Reduction of water evaporation in polymerase chain reaction microfluidic devices based on oscillating-flow.

Authors:  Alessandro Polini; Elisa Mele; Anna Giovanna Sciancalepore; Salvatore Girardo; Adriana Biasco; Andrea Camposeo; Roberto Cingolani; David A Weitz; Dario Pisignano
Journal:  Biomicrofluidics       Date:  2010-09-01       Impact factor: 2.800

3.  Acetylated bovine serum albumin differentially inhibits polymerase chain reaction in microdevices.

Authors:  Naveen Ramalingam; Majid Ebrahimi Warkiani; Thomas Hai-Qing Gong
Journal:  Biomicrofluidics       Date:  2017-05-17       Impact factor: 2.800

Review 4.  Droplet microfluidics for high-sensitivity and high-throughput detection and screening of disease biomarkers.

Authors:  Aniruddha M Kaushik; Kuangwen Hsieh; Tza-Huei Wang
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2018-05-24

5.  Evaluation of a high-throughput, microfluidics platform for performing TaqMan™ qPCR using formalin-fixed paraffin-embedded tumors.

Authors:  Ping Li; Elena Grigorenko; Vince Funari; Edward Enright; Hao Zhang; Hyung L Kim
Journal:  Bioanalysis       Date:  2013-07       Impact factor: 2.681

6.  An Analysis of Quantitative PCR Reliability Through Replicates Using the C Method.

Authors:  Chris C Stowers; Frederick R Haselton; Erik M Boczko
Journal:  J Biomed Sci Eng       Date:  2010-05

7.  High-throughput quantitative polymerase chain reaction in picoliter droplets.

Authors:  Margaret Macris Kiss; Lori Ortoleva-Donnelly; N Reginald Beer; Jason Warner; Christopher G Bailey; Bill W Colston; Jonathon M Rothberg; Darren R Link; John H Leamon
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

8.  Nanoliter high throughput quantitative PCR.

Authors:  Tom Morrison; James Hurley; Javier Garcia; Karl Yoder; Arrin Katz; Douglas Roberts; Jamie Cho; Tanya Kanigan; Sergey E Ilyin; Daniel Horowitz; James M Dixon; Colin J H Brenan
Journal:  Nucleic Acids Res       Date:  2006-09-25       Impact factor: 16.971

Review 9.  Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends.

Authors:  Chunsun Zhang; Da Xing
Journal:  Nucleic Acids Res       Date:  2007-06-18       Impact factor: 16.971

10.  Microfluidic droplet-based PCR instrumentation for high-throughput gene expression profiling and biomarker discovery.

Authors:  Christopher J Hayes; Tara M Dalton
Journal:  Biomol Detect Quantif       Date:  2015-06-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.