Literature DB >> 1562431

Slotted versus non-slotted locked intramedullary nailing for femoral shaft fractures.

A Alho1, O Moen, T Husby, H Rønningen, S Skjeldal.   

Abstract

Experimentally, two slotted nails, the Grosse-Kempf nail and the AO/ASIF universal femoral nail, were compared to the non-slotted Grosse-Kempf nail and control bone using a cadaver femoral osteotomy. The stiffnesses and strengths of the osteotomies fixed with slotted nails in 10-30 degrees torsion were 6-8% and the values of non-slotted nails 40% of control bone. The maximal moments were 14-18% and 48%, respectively. In the "clinical range" of torsion, the implant-bone construct never failed or was deformed. Clinically, 46 femoral shaft fractures were randomized to treatment with Gross-Kempf nails, 24 with slotted nails and 22 with non-slotted nails. Four complications in the slotted nail group and three in the non-slotted nail group were considered to be independent of the choice of nail and did not affect the end result. Three splinterings of the distal fragment, one resulting in a change of the osteosynthesis implant to a condylar plate, were considered to result from the high stiffness of the non-slotted nail. Osteosynthesis of femoral shaft fractures using slotted nails has not resulted in healing disturbances, which could be accounted for by the high torsional elasticity of the nail; there seems to be no indication for high-stiffness nails in femoral fractures.

Entities:  

Mesh:

Year:  1992        PMID: 1562431     DOI: 10.1007/bf00443474

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  14 in total

1.  [Treatment of fragments, loss of bony substance and pseudarthrosis of femur and tibia using screw fixation (40 cases)].

Authors:  A Grosse; I Kempf; D Lafforgue
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1978

2.  [Blind nailing with reaming in fractures of the femoral shaft. Technique, indications, and results in 399 cases].

Authors:  J Decoulx; I Kempf; G Jenny; E Schvingt; P Petit; P Vives
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1975-09

3.  Rotational strength of the femoral neck. Computed tomography in cadavers.

Authors:  T Husby; A Høiseth; A Alho; H Rønningen
Journal:  Acta Orthop Scand       Date:  1989-06

4.  [Dynamic and static locking of the intramedullary nail].

Authors:  K Klemm; W D Schellmann
Journal:  Monatsschr Unfallheilkd Versicher Versorg Verkehrsmed       Date:  1972-12

5.  Mechanical failure of intramedullary nails after fracture union.

Authors:  K W Zimmerman; H J Klasen
Journal:  J Bone Joint Surg Br       Date:  1983-05

6.  [Principles of interlocking nailing--biomechanical principles].

Authors:  V Vécsei
Journal:  Hefte Unfallheilkd       Date:  1983

7.  Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases.

Authors:  R A Winquist; S T Hansen; D K Clawson
Journal:  J Bone Joint Surg Am       Date:  1984-04       Impact factor: 5.284

8.  [The risk non-union following closed-focus nailing and reaming. Results of 1059 interventions using the Kunstcher method].

Authors:  S R Babin; P Graf; P Vidal; N Sur; E Schvingt
Journal:  Int Orthop       Date:  1983       Impact factor: 3.075

9.  Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.

Authors:  Y Onoue; Y Sunami; H Fujiwara; T Sadakane; S Yasuda
Journal:  Int Orthop       Date:  1979       Impact factor: 3.075

10.  Interlocking intramedullary nailing in femoral shaft fractures. A report of forty-eight cases.

Authors:  B O Thoresen; A Alho; A Ekeland; K Strømsøe; G Follerås; A Haukebø
Journal:  J Bone Joint Surg Am       Date:  1985-12       Impact factor: 5.284

View more
  1 in total

1.  Low success rate of non-intervention after breakage of interlocking nails.

Authors:  Chi-Chuan Wu; Zhon-Liau Lee
Journal:  Int Orthop       Date:  2005-02-01       Impact factor: 3.075

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.