Literature DB >> 15624169

Discontinuous electrolyte systems for improved detection of biologically active amines and acids by capillary electrophoresis with laser-induced native fluorescence detection.

Ming-Mu Hsieh1, Huan-Tsung Chang.   

Abstract

On-line concentration and separation of biologically active amines and acids by capillary electrophoresis (CE) in conjunction with laser-induced fluorescence using an Nd:YAG laser at 266 nm under discontinuous conditions is presented. The suitable conditions for simultaneous analysis of amines and acids were: samples were prepared in a solution (pH* 3.1) consisting of 10 mM citric acid, 89% acetonitrile (ACN), and water; a capillary was filled with 1.5 M Tris-borate (TB) buffer (pH 10.0); and the anodic vial contained PTG10 buffer (pH* 9.0) that consists of 50 mM propanoic acid, Tris, 10% glycerol, and water. After injecting a large-volume sample, amines and acids were separately stacked at the front (cathodic side) and back (anodic side) of the acidic sample zone, mainly because of changes in their electrophoretic mobilities as a result of changes in pH, viscosity, and electric field when high voltage was applied. When the sample was injected at 15 kV for 360 s, the concentration limits of detection (LODs) for 5-hydroxytryptamine (5-HT) and 5-hydroxyindole-3-acetic acid (5-HIAA) were 0.27 and 0.31 nM, respectively, which are about 400- and 800-fold sensitivity improvements when compared to those injected at 1 kV for 10 s. For the analysis of amines, samples were prepared in 100 mM citric acid (pH* 1.8) containing 89% ACN and both the capillary and anodic vial were filled with 400 mM PTG20 (propanoic acid, Tris, 20% glycerol, and water) at pH* 4.5. Using a large injection volume (15 kV for 360 s), we achieved concentration LODs of 17 pM and 0.3 nM for tryptamine and epinephrine, which are about 5200- and 14,000-fold sensitivity improvements, respectively, in comparison with those injected at 1 kV for 10 s. The features of simplicity (no sample pretreatment), rapidity (12 min), and sensitivity for identification of amines and acids of interest in urine samples show diagnostic potential of the two approaches developed in this study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15624169     DOI: 10.1002/elps.200406123

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  2 in total

1.  Enhanced pH-mediated stacking of anions for CE incorporating a dynamic pH junction.

Authors:  Stacy D Arnett; Craig E Lunte
Journal:  Electrophoresis       Date:  2007-10       Impact factor: 3.535

2.  A serotonin voltammetric biosensor composed of carbon nanocomposites and DNA aptamer.

Authors:  Jingjing Li; Yunpei Si; Yae Eun Park; Jung-Seok Choi; Sung Mi Jung; Ji Eun Lee; Hye Jin Lee
Journal:  Mikrochim Acta       Date:  2021-04-01       Impact factor: 5.833

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.