A prospective comparison of 99mTc-labeled polyclonal human immunoglobulin and 111In granulocytes for localization of inflammatory bowel disease.

J W Arndt1, A van der Sluys Veer, D Blok, G Griffioen, H W Verspaget, A S Peña, C B Lamers, E K Pauwels.   

Abstract

There is a need for an easily prepared radiopharmaceutical agent for the detection of inflammation and infection. In a group of 14 patients with inflammatory bowel disease (IBD), the detection of actively involved intestinal segments by nonspecific human polyclonal immunoglobulin (IgG) labeled with 99mTc was compared with that of 111In granulocytes. To determine the specificity of 99mTc-IgG scintigraphy, 8 control patients without clinical indications of intestinal inflammation were examined. 99mTc-IgG was found in the left colon in 8 and in the right colon in 7 of the 8 controls 4 hours after the injection. At that time of scintigraphy only 4 IBD patients exhibited a more intense accumulation at the site of the intestinal segments with active disease. In contrast, in a randomized comparison with 111In granulocytes scintigraphy was positive in 11 patients with the latter technique. Moreover, fewer diseased segments were seen in the 4 patients with positive 99mTc-IgG scintigraphy (6 versus 12 with 111In granulocytes). In view of the low sensitivity and specificity, it is concluded that 99mTc-IgG is not suitable for the scintigraphic staging of IBD patients.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1562407

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  5 in total

1.  Inflammatory bowel disease activity assessment using technetium-99m-HMPAO leukocytes.

Authors:  J W Arndt; M I Grootscholten; R A van Hogezand; G Griffioen; C B Lamers; E K Pauwels
Journal:  Dig Dis Sci       Date:  1997-02       Impact factor: 3.199

Review 2.  Radiotracers used for the scintigraphic detection of infection and inflammation.

Authors:  Chris Tsopelas
Journal:  ScientificWorldJournal       Date:  2015-02-08

3.  Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

Authors:  E T Dams; M M Reijnen; W J Oyen; O C Boerman; P Laverman; G Storm; J W van der Meer; F H Corstens; H van Goor
Journal:  Ann Surg       Date:  1999-04       Impact factor: 12.969

4.  Anti-granulocyte immunoscintigraphy and [99mTc]hexamethylpropyleneamine-oxime-labeled leukocyte scintigraphy in inflammatory bowel disease.

Authors:  M Papos; F Nagy; G Narai; M Rajtar; G Szantai; J Lang; L Csernay
Journal:  Dig Dis Sci       Date:  1996-02       Impact factor: 3.199

5.  Simultaneous administration of 111In-human immunoglobulin and 99mTc-HMPAO labelled leucocytes in inflammatory bowel disease.

Authors:  L Mairal; P A de Lima; J Martin-Comin; C Baliellas; X Xiol; M Roca; Y Ricart; M Ramos
Journal:  Eur J Nucl Med       Date:  1995-07