Literature DB >> 15623061

Immediate restoration of single-tooth implants in mandibular molar sites: a 12-month preliminary report.

Roberto Cornelini1, Filippo Cangini, Ugo Covani, Antonio Barone, Daniel Buser.   

Abstract

PURPOSE: The aim of this prospective clinical study was to evaluate the survival rates at 12 months of transmucosal implants placed in the posterior mandible and immediately restored with single crowns.
MATERIALS AND METHODS: Thirty ITI dental implants with sandblasted, acid-etched surfaces were placed in 30 patients missing at least 1 mandibular molar and immediately restored if acceptable primary stability was attained. Primary stability was measured with resonance frequency analysis (RFA) using the Osstell device, and only implants with a stability quotient greater than 62 were included in the study. RFA measurement and radiographic assessment were made at baseline and 6 months after implant placement. Plaque Index, Bleeding Index, probing depth, attachment level, and width of keratinized tissue were measured at the 12 month follow-up examination.
RESULTS: At 12 months, only 1 implant had been lost; it was removed because of acute infection. Radiographic as well as clinical examination confirmed osseointegration of all implants, with a survival rate of 96.7%. DISCUSSION: Interestingly, implant stability as measured using RFA did not increase significantly from baseline to 12 months (P > .05).
CONCLUSION: The present study showed that immediate restoration of transmucosal implants placed in the mandibular area with good primary stability can be a safe and successful procedure. However, larger, long-term clinical trials are needed to confirm the present results.

Entities:  

Mesh:

Year:  2004        PMID: 15623061

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Immediate vs non-immediate loading post-extractive implants: a comparative study of implant stability quotient (ISQ).

Authors:  L Milillo; C Fiandaca; F Giannoulis; L Ottria; A Lucchese; F Silvestre; M Petruzzi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

2.  Biomimetic treatment on dental implants for short-term bone regeneration.

Authors:  Francisco Javier Gil; Norberto Manzanares; Armando Badet; Conrado Aparicio; Maria-Pau Ginebra
Journal:  Clin Oral Investig       Date:  2013-03-08       Impact factor: 3.573

3.  Vibrational analysis of mandible trauma: experimental and numerical approaches.

Authors:  Shu-Li Lin; Sheng-Yang Lee; Long-Yi Lee; Wen-Ta Chiu; Che-Tong Lin; Haw-Ming Huang
Journal:  Med Biol Eng Comput       Date:  2006-08-22       Impact factor: 2.602

4.  Effect of Light Emitting Diode Photobiomodulation on the Stability of Dental Implants in Bone Grafted Cases: a Split-Mouth Randomized Clinical Trial.

Authors:  Atabak Kashefimehr; Mahdi Rahbar; Masoumeh Faramarzi; Amirreza Babaloo; Mehrnoosh Sadighi; Abbas Goshaderoo
Journal:  Maedica (Bucur)       Date:  2021-06

5.  Immediately Loaded Single Unit Dental Implants: A Clinical Study.

Authors:  Shweta Rai; Anurag Rai; Tanoj Kumar; Minti Kumari; Muthyalu Kumar Somanna; Subhash Bandgar
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

6.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11

7.  Early loading of hydrophilic titanium implants inserted in low-mineralized (D3 and D4) bone: one year results of a prospective clinical trial.

Authors:  Uwe Held; Dennis Rohner; Daniel Rothamel
Journal:  Head Face Med       Date:  2013-12-09       Impact factor: 2.151

8.  FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods.

Authors:  M Cicciù; G Cervino; E Bramanti; F Lauritano; G Lo Gudice; L Scappaticci; A Rapparini; E Guglielmino; G Risitano
Journal:  Comput Math Methods Med       Date:  2015-12-21       Impact factor: 2.238

9.  Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling.

Authors:  Rokhsareh Sadeghi; Amir Reza Rokn; Asghar Miremadi
Journal:  J Dent (Tehran)       Date:  2015-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.