Improving the fit of implant-supported superstructures using the spark erosion technique.

Eduard Eisenmann1, Ali Mokabberi, Michael H Walter, Wolfgang B Freesmeyer.   

Abstract

PURPOSE: The purpose of this study was to determine whether the passive fit of the implant-retained single-cast framework could be improved by spark erosion treatment.
MATERIALS AND METHODS: An initial cast was produced in a transparent resin material. Five Branemark System implants were arranged in the interforaminal region, and abutments were placed on them with a torque of 20 Ncm. An impression was made using a standard impression technique described by Branemark. A corresponding master cast suitable for the spark erosion post-framework fabrication was produced. From this master cast, 12 frameworks were produced in a conventional single-cast procedure. Six of these were made of a high-gold alloy (Stabilor G); the other 6 were made of pure titanium (Biotan). These frameworks were then refined using the SAE Secotec Spark Erosion System. To measure the accuracy of the framework fit, the frameworks were measured before and after the spark erosion treatment using 2 different measurement methods-scanning electron microscopy to measure the gap widths (Sheffield test) and photoelastic stress analysis.
RESULTS: The results of both measurement techniques correlated and demonstrated significant improvement in the accuracy of fit or in the passive fit for all 12 frameworks after spark erosion treatment. This improvement was statistically significant for the titanium frameworks. DISCUSSION: Dental practitioners and technicians should strive to achieve a precise passive fit of frameworks and superstructures to minimize additional stress at the interfaces of the prosthesis, abutment, and implant.
CONCLUSION: The clinical use of the spark erosion technique to refine framework fit is recommended. (More than 50 references.)

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15623055

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

2.  Multitechnique characterization of CPTi surfaces after electro discharge machining (EDM).

Authors:  Spiros Zinelis; Youssef S Al Jabbari; Andrew Thomas; Nick Silikas; George Eliades
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

3.  Three-dimensional accuracy of different correction methods for cast implant bars.

Authors:  Ji-Yung Kwon; Chang-Whe Kim; Young-Jun Lim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

4.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

5.  Errors in Implant Positioning Due to Lack of Planning: A Clinical Case Report of New Prosthetic Materials and Solutions.

Authors:  Marco Tallarico; Roberto Scrascia; Marco Annucci; Silvio Mario Meloni; Aurea Immacolata Lumbau; Alba Koshovari; Erta Xhanari; Matteo Martinolli
Journal:  Materials (Basel)       Date:  2020-04-16       Impact factor: 3.623

6.  Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys.

Authors:  Hang-Nga Mai; Tae-Yub Kwon; Min-Ho Hong; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2018-08-05       Impact factor: 3.411

7.  Rehabilitation of a maxillary partial edentulous patient using an implant-supported overdenture retained with two bilateral milled bars.

Authors:  Atif Mohammed Almadani; Fabian Huettig
Journal:  BMJ Case Rep       Date:  2020-08-24

8.  Effect of Laser Etching and Spark Erosion on Retention and Resistance of Partial Veneer Crown Copings Luted with Adhesive Resin Cement.

Authors:  Chandra Govindaraj Sarath; Sivanesan Karthikeyan Jagdish; Krishnan Murugesan; Balasubramaniam Muthukumar
Journal:  Contemp Clin Dent       Date:  2018-09
  8 in total