Thoracic aneurysm rupture due to graft perforation after endovascular stent-grafting via median sternotomy.

Masashi Toyama1, Akihiko Usui, Masaharu Yoshikawa, Yuichi Ueda.   

Abstract

We performed emergency repeat surgery for aneurismal rupture due to graft perforation with mechanical stress of the Z stent in a kinking graft after frozen elephant trunk procedure. Graft kinking occurred due to cranial migration of the Z stent. It is important to prevent stent dislodgement in order to achieve long-term durability and reliability in the frozen elephant trunk procedure.

Entities:  

Mesh:

Year:  2005        PMID: 15621493     DOI: 10.1016/j.ejcts.2004.09.007

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191