Literature DB >> 15620933

Reoperation for false aneurysm of the ascending aorta after its prosthetic replacement: surgical strategy.

Siamak Mohammadi1, Nicolas Bonnet, Pascal Leprince, Mohamed Kolsi, Akhtar Rama, Alain Pavie, Iradj Gandjbakhch.   

Abstract

BACKGROUND: This study analyzes surgical approaches of 29 operations carried out for false aneurysms of the ascending aorta after prosthetic replacement (FAA) from January 1979 to April 2003, in 28 patients.
METHODS: Initial operations consisted of a composite valve graft with reimplantation of coronary arteries (n = 14) or a supracoronary tube (n = 14) with 7 aortic valve replacements. Initial pathology included acute aortic dissection (n = 20), aortic annuloectasia (n = 6), and aortic valvulopathies with concomitant aneurysm of the ascending aorta (n = 2). Resternotomy was performed under the following conditions: femoral artery cannulation in 7, femoral artery and vein cannulation in 6, femoral artery, vein, and carotid artery cannulation in 16 patients of whom 6 patients underwent partial circulatory arrest. The FAA ruptured during sternotomy in 9 cases. Operative intervention consisted of direct simple suture repair (n = 7), complete revision (n = 21), and one isolated reimplantation of the coronary artery.
RESULTS: No patients died after FAA rupture during resternotomy. Among the 6 patients who underwent partial circulatory arrest before sternotomy, the FAA ruptured 5 times. Carotid artery cannulation was always justifiable: 2 cases of FAA rupture, 9 cases of aortic arch replacement, and 5 cases with both. The operative mortality was 17.2% (n = 5). Mortality was influenced by the emergent nature of operations (p < 0.05).
CONCLUSIONS: The FAA can be surgically managed with acceptable results through a sternotomy using prior femoro-femoral and carotid cannulation. The latter allows for cerebral perfusion in cases of FAA rupture during resternotomy and is of value for the surgical treatment of these complex lesions.

Entities:  

Mesh:

Year:  2005        PMID: 15620933     DOI: 10.1016/j.athoracsur.2004.06.032

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  26 in total

1.  Repair of ascending aorta pseudoaneurysm without circulatory arrest in redo patient.

Authors:  Stefano Auriemma; Paolo Magagna; Ayman Sallam; Nicola Lamascese; Alessandro Fabbri
Journal:  World J Emerg Surg       Date:  2006-03-24       Impact factor: 5.469

2.  Double pseudoaneurysm, recurrent subvalvular aortic membrane and small left ventricular outflow tract in the same patient: who dares?

Authors:  Rocío Díaz; Daniel Hernandez-Vaquero; Rubén Álvarez-Cabo; Isaac Pascual; Cecilia Corros; Alberto Alperi; Jose Rozado; Jacobo Silva; César Morís
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

3.  Surgical management of a giant ascending aortic pseudoaneurysm.

Authors:  Juan D Garisto; Andres Medina; Donald B Williams; Roger G Carrillo
Journal:  Tex Heart Inst J       Date:  2010

Review 4.  Postoperative imaging of the aorta.

Authors:  Weier Li; Sasiprapa Rongthong; Anand M Prabhakar; Sandeep Hedgire
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

5.  Surgical Strategy for Thoracic Aortic Pseudoaneurysm with Sternal Adherence.

Authors:  Yu Inaba; Tsutomu Ito; Sachiko Hayashi; Yasunori Iida; Takahiko Misumi; Hideyuki Shimizu
Journal:  Ann Vasc Dis       Date:  2016-07-26

6.  Aneurysmal dilation of the ascending thoracic aorta and the aortic arch following surgical repair of type A dissection.

Authors:  Suzanne M Cormack; W Andrew Owens
Journal:  BMJ Case Rep       Date:  2012-10-12

7.  Giant pseudoaneurysm of the ascending aorta after valve replacement. Medical follow-up for 22 months without complication.

Authors:  G Cabuk; Y Guray; S Okten; O Tufekcioglu; U Guray
Journal:  Herz       Date:  2013-03-28       Impact factor: 1.443

8.  A Tale of Three Surgeries: Management of a Massive Recurrent Mycotic Aortic Pseudoaneurysm.

Authors:  Megan D Henley; Mark A Farber; John S Ikonomidis; Lavinia M Kolarczyk; Emily G Teeter; Brian P Barrick; Thomas G Caranasos; Susan M Martinelli
Journal:  J Cardiothorac Vasc Anesth       Date:  2017-08-26       Impact factor: 2.628

9.  Aorto-Cutaneous Fistula and False Aneurysm of the Ascending Aorta Five Years after its Prosthetic Replacement for Stanford Type A Acute Aortic Dissection.

Authors:  Pierre Demondion; Dorian Verscheure; Pascal Leprince
Journal:  Aorta (Stamford)       Date:  2017-04-01

10.  Repeat surgical intervention after aortic repair for acute Stanford type A dissection.

Authors:  Tadashi Kitamura; Shinzo Torii; Kensuke Kobayashi; Yuki Tanaka; Akihiro Sasahara; Haruna Araki; Yuki Ohtomo; Rihito Horikoshi; Kagami Miyaji
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-08-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.