Literature DB >> 15617282

Fiber loop ringdown for physical sensor development: pressure sensor.

Chuji Wang1, Susan T Scherrer.   

Abstract

A new method of developing optical fiber pressure sensors by use of a fiber loop ringdown scheme is described. The fiber loop ringdown system is characterized in terms of the ringdown baseline stability, fiber transmission loss, and fiber refractive index. The overall sensor performance is demonstrated by use of sensing forces applied to the sensor head. The current device can sense pressures in the range of 0 to 9.8 x 10(6) Pa, converted approximately from the applied forces. The sensor's linear response, repeatability, detection sensitivity, measuring dynamic range, and temperature tolerance are explored.

Entities:  

Year:  2004        PMID: 15617282     DOI: 10.1364/ao.43.006458

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  5 in total

Review 1.  Chemical sensing using fiber cavity ring-down spectroscopy.

Authors:  Helen Waechter; Jessica Litman; Adrienne H Cheung; Jack A Barnes; Hans-Peter Loock
Journal:  Sensors (Basel)       Date:  2010-03-02       Impact factor: 3.576

2.  Fiber loop ringdown - a time-domain sensing technique for multi-function fiber optic sensor platforms: current status and design perspectives.

Authors:  Chuji Wang
Journal:  Sensors (Basel)       Date:  2009-09-28       Impact factor: 3.576

3.  Continuous-Wave Fiber Cavity Ringdown Pressure Sensing Based on Frequency-Shifted Interferometry.

Authors:  Yiwen Ou; Chunfu Cheng; Zehao Chen; Zhangyong Yang; Hui Lv; Li Qian
Journal:  Sensors (Basel)       Date:  2018-04-16       Impact factor: 3.576

4.  Fiber loop ringdown sensor for potential real-time monitoring of cracks in concrete structures: an exploratory study.

Authors:  Peeyush Sahay; Malik Kaya; Chuji Wang
Journal:  Sensors (Basel)       Date:  2012-12-20       Impact factor: 3.576

5.  Hybrid Structure Multichannel All-Fiber Current Sensor.

Authors:  Junzhen Jiang; Hao Zhang; Youwu He; Yishen Qiu
Journal:  Sensors (Basel)       Date:  2017-08-02       Impact factor: 3.576

  5 in total