Literature DB >> 15617265

Glucose-sensitive nanoassemblies comprising affinity-binding complexes trapped in fuzzy microshells.

Swetha Chinnayelka1, Michael J McShane.   

Abstract

A new design for glucose monitoring with "smart" materials based on self assembly, competitive binding, and resonance energy transfer (RET) is presented. The basic transduction principle is changing RET efficiency from fluorescein isothiocyanate (FITC) to tetramethylrhodamine isothiocyanate (TRITC), as FITC-dextran is displaced from TRITC-Concanavalin A (Con A) with the addition of glucose. Nanoscale fabrication by self-assembly of Con A/dextran into multilayer films, followed by polymer multilayers. The advantages of this approach include physical localization and separation of sensing molecules from the environment via entrapment of the biosensorelements in a semi-permeable polymeric shell, and only functional molecules are included in the sensors. To realize these nanostructures, dissolvable resin microparticles were coated with FITC-dextran+TRITC-Con A multilayers, followed by polyelectrolyte multilayers, and the core particles were then dissolved to yield hollow capsules. The nanoassembly process was studied using microbalance mass measurements, fluorescence spectroscopy, confocal fluorescence microscopy, and zeta-potential measurements. The key findings are that the specific binding between Con A and dextran can be used to deposit ultrathin multilayer films, and these exhibit changing RET in response to glucose. Fluorescence spectra of a microcapsules exhibited a linear, glucose-specific, 27% increase in the relative fluorescence of FITC over the 0-1800 mg/dL range. These findings demonstrate the feasibility of using self-assembled microcapsules as optical glucose sensors, and serve as a basis for work toward better understanding the properties of these novel materials.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15617265      PMCID: PMC4465401          DOI: 10.1023/b:jofl.0000039345.57924.f3

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  16 in total

1.  Insulin delivery governed by covalently modified lectin-glycogen gels sensitive to glucose.

Authors:  S Tanna; M J Taylor; G Adams
Journal:  J Pharm Pharmacol       Date:  1999-10       Impact factor: 3.765

2.  Monte Carlo modeling for implantable fluorescent analyte sensors.

Authors:  M J McShane; S Rastegar; M Pishko; G L Coté
Journal:  IEEE Trans Biomed Eng       Date:  2000-05       Impact factor: 4.538

3.  Glucose monitoring using implanted fluorescent microspheres.

Authors:  M J McShane; R J Russell; M V Pishko; G L Coté
Journal:  IEEE Eng Med Biol Mag       Date:  2000 Nov-Dec

4.  Molecular distribution sensing in a fluorescence resonance energy transfer based affinity assay for glucose.

Authors:  O J Rolinski; D J Birch; L McCartney; J C Pickup
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2001-09-14       Impact factor: 4.098

5.  Potential for glucose monitoring with nanoengineered fluorescent biosensors.

Authors:  Michael J McShane
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

6.  Polyelectrolyte microshells as carriers for fluorescent sensors: loading and sensing properties of a ruthenium-based oxygen indicator.

Authors:  Michael J McShane; J Quincy Brown; Kyle B Guice; Yuri M Lvov
Journal:  J Nanosci Nanotechnol       Date:  2002 Jun-Aug

7.  A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel.

Authors:  R J Russell; M V Pishko; C C Gefrides; M J McShane; G L Coté
Journal:  Anal Chem       Date:  1999-08-01       Impact factor: 6.986

Review 8.  Biosensors--what real progress is being made?

Authors:  D Griffiths; G Hall
Journal:  Trends Biotechnol       Date:  1993-04       Impact factor: 19.536

Review 9.  Resonance energy transfer: methods and applications.

Authors:  P Wu; L Brand
Journal:  Anal Biochem       Date:  1994-04       Impact factor: 3.365

10.  Affinity sensor: a new technique for developing implantable sensors for glucose and other metabolites.

Authors:  J S Schultz; S Mansouri; I J Goldstein
Journal:  Diabetes Care       Date:  1982 May-Jun       Impact factor: 19.112

View more
  16 in total

1.  Three-dimensional, multiwavelength Monte Carlo simulations of dermally implantable luminescent sensors.

Authors:  Ruiqi Long; Mike McShane
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Microporated PEG spheres for fluorescent analyte detection.

Authors:  Rebecca M Rounds; Bennett L Ibey; Hope T Beier; Michael V Pishko; Gerard L Coté
Journal:  J Fluoresc       Date:  2006-11-17       Impact factor: 2.217

Review 3.  A glucose-sensing contact lens: from bench top to patient.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Curr Opin Biotechnol       Date:  2005-02       Impact factor: 9.740

4.  Enzymatic fluorescent microsphere glucose sensors:evaluation of response under dynamic conditions.

Authors:  J Quincy Brown; Rohit Srivastava; Huiguang Zhu; Michael J McShane
Journal:  Diabetes Technol Ther       Date:  2006-06       Impact factor: 6.118

5.  Concanavalin A-polysaccharides binding affinity analysis using a quartz crystal microbalance.

Authors:  Fohona S Coulibaly; Bi-Botti C Youan
Journal:  Biosens Bioelectron       Date:  2014-03-31       Impact factor: 10.618

6.  Fiber-coupled fluorescence affinity sensor for 3-day in vivo glucose sensing.

Authors:  Ralph Ballerstadt; Colton Evans; Ashok Gowda; Roger McNichols
Journal:  J Diabetes Sci Technol       Date:  2007-05

7.  Glucose sensors based on microcapsules containing an orange/red competitive binding resonance energy transfer assay.

Authors:  Swetha Chinnayelka; Michael J McShane
Journal:  Diabetes Technol Ther       Date:  2006-06       Impact factor: 6.118

8.  Experimental validation of an optical system for interrogation of dermally-implanted microparticle sensors.

Authors:  Ruiqi Long; Mike McShane
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

9.  Dissolved core alginate microspheres as "smart-tattoo" glucose sensors.

Authors:  Ayesha Chaudhary; Monica Raina; Michael J McShane; Rohit Srivastava
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

10.  Preclinical in vivo study of a fluorescence affinity sensor for short-term continuous glucose monitoring in a small and large animal model.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Ashok Gowda; Roger McNichols
Journal:  Diabetes Technol Ther       Date:  2008-12       Impact factor: 6.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.