Literature DB >> 15616227

A two-center randomized controlled feasibility trial of insulin pump therapy in young children with diabetes.

Darrell M Wilson1, Bruce A Buckingham, Elizabeth L Kunselman, Mary M Sullivan, Helen U Paguntalan, Stephen E Gitelman.   

Abstract

OBJECTIVE: Our goals were to determine if continuous subcutaneous insulin infusion (CSII), compared with those continuing multiple daily injections (MDIs), can be safely used in young children, if those on CSII will have superior glycemic control, if subjects using CSII will have less hypoglycemia for their level of control, and if families using CSII will report an improved quality of life. RESEARCH DESIGN AND METHODS: We conducted a randomized 1-year feasibility trial comparing CSII with continuing MDIs in preschool children with a history of type 1 diabetes for at least 6 months' duration. Prospective outcomes included measures of overall glycemic control (HbA1c and continuous glucose monitoring system), the incidence of severe hypoglycemia and diabetic ketoacidosis, the percent of glucose values below 3.9 mmol/l, and the parents' report of quality of life.
RESULTS: The 19 subjects' ages ranged from 1.7 to 6.1 (mean 3.6) years, duration of diabetes ranged from 0.6 to 2.6 (mean 1.4) years, and baseline HbA1c ranged from 6.7 to 9.6% (mean 7.9%). Seven subjects were male. Nine subjects were randomized to start CSII and 10 to continue on MDI. All baseline characteristics were well balanced. Overall metabolic control, diabetes quality of life, and the incidence of hypoglycemia were similar in the two groups. No subject had diabetic ketoacidosis, while one subject in each group had an episode of severe hypoglycemia. No CSII subject discontinued using the pump during or after the study.
CONCLUSIONS: CSII can be a safe and effective method to deliver insulin in young children.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15616227     DOI: 10.2337/diacare.28.1.15

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  33 in total

1.  Use of lispro insulin diluted with normal saline to 10 U/ml in an insulin pump: case report.

Authors:  Beata Mianowska; Agnieszka Szadkowska; Wojciech Fendler; Wojciech Mlynarski
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

Review 2.  The evidence base for diabetes technology: appropriate and inappropriate meta-analysis.

Authors:  John C Pickup
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

Review 3.  Continuous subcutaneous insulin infusion versus multiple daily injections in individuals with type 1 diabetes: a systematic review and meta-analysis.

Authors:  Khalid Benkhadra; Fares Alahdab; Shrikant U Tamhane; Rozalina G McCoy; Larry J Prokop; Mohammad Hassan Murad
Journal:  Endocrine       Date:  2016-08-01       Impact factor: 3.633

4.  STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects.

Authors:  Stephen N Davis; Edward S Horton; Tadej Battelino; Richard R Rubin; Kevin A Schulman; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2010-04       Impact factor: 6.118

5.  A population-based study of risk factors for severe hypoglycaemia in a contemporary cohort of childhood-onset type 1 diabetes.

Authors:  Matthew N Cooper; Susan M O'Connell; Elizabeth A Davis; Timothy W Jones
Journal:  Diabetologia       Date:  2013-07-06       Impact factor: 10.122

Review 6.  Management of diabetes mellitus in infants.

Authors:  Beate Karges; Thomas Meissner; Andrea Icks; Thomas Kapellen; Reinhard W Holl
Journal:  Nat Rev Endocrinol       Date:  2011-11-29       Impact factor: 43.330

Review 7.  Quality of life and technology: impact on children and families with diabetes.

Authors:  Masakazu Hirose; Elizabeth A Beverly; Katie Weinger
Journal:  Curr Diab Rep       Date:  2012-12       Impact factor: 4.810

8.  Practical experience with continuous subcutaneous insulin infusion therapy in a pediatric diabetes clinic.

Authors:  Michele A O'Connell; Fergus J Cameron
Journal:  J Diabetes Sci Technol       Date:  2008-01

Review 9.  Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta-analysis.

Authors:  K Jeitler; K Horvath; A Berghold; T W Gratzer; K Neeser; T R Pieber; A Siebenhofer
Journal:  Diabetologia       Date:  2008-03-20       Impact factor: 10.122

10.  Long-term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study.

Authors:  Stephanie R Johnson; Matthew N Cooper; Timothy W Jones; Elizabeth A Davis
Journal:  Diabetologia       Date:  2013-08-21       Impact factor: 10.122