Literature DB >> 15615557

Elective stent-graft treatment of aortic dissections.

Kwang-Hun Lee1, Jong Yun Won, Do Yun Lee, Donghoon Choi, Won-Heum Shim, Byung Chul Chang.   

Abstract

PURPOSE: To retrospectively review 8 years' experience with stent-graft treatment of aortic dissections at a single institution.
METHODS: Forty-six patients (31 men; mean age 59 years, range 38-88) underwent stent-graft treatment for 9 Stanford type A and 37 type B aortic dissections (9 acute phase, 13 subacute, 24 chronic). Custom-designed self-expanding stainless steel Z stents covered with polytetrafluoroethylene were used (n=20) until low-profile modular stent-grafts became available for percutaneous delivery (n=26).
RESULTS: Endovascular stent-graft deployment was technically successful in 44 (96%) patients; the 2 failed cases owing to intraprocedural migration and graft torsion were converted to surgery. There were 5 type I endoleaks for a clinical success (entry tear exclusion) of 85% (39/46). Complications included 3 cases of transient renal failure, 2 puncture site pseudoaneurysms, 1 guidewire-induced new intimal tear (converted), and 2 cases of stent-induced saccular aneurysms (1 converted). Follow-up at a mean 34 months (range 12-96) showed complete resolution of the thoracic false lumen in 14 (74%) of 19 acute/subacute patients treated successfully; 3 (16%) showed a reduced thoracic false lumen diameter. In the 23 chronic-phase patients treated successfully, 8 (35%) had complete resolution of the thoracic false lumen, and 11 (48%) showed size reduction. Enlargement of the abdominal aortic false lumen due to persistent flow into re-entry tear(s) occurred in 3 (13%).
CONCLUSIONS: Stent-graft treatment is a feasible and effective treatment modality in aortic dissection. However, close follow-up is mandatory to monitor new intimal tear, saccular aneurysms, or enlargement of the abdominal aortic false lumen.

Entities:  

Mesh:

Year:  2004        PMID: 15615557     DOI: 10.1583/1220MR.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  Application of thoracic endovascular dissecting aneurysm repair for secondary type B aortic dissection.

Authors:  Oguz Karahan; Orhan Tezcan; Sinan Demirtas; Ahmet Caliskan; Celal Yavuz
Journal:  Cardiovasc J Afr       Date:  2015-11-23       Impact factor: 1.167

Review 2.  Retrograde Type A Aortic Dissection After Thoracic Endovascular Aortic Repair: A Systematic Review and Meta-Analysis.

Authors:  Yanqing Chen; Simeng Zhang; Lei Liu; Qingsheng Lu; Tianyi Zhang; Zaiping Jing
Journal:  J Am Heart Assoc       Date:  2017-09-22       Impact factor: 5.501

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.