Literature DB >> 15615552

Percutaneous AAA repair: is it safe?

Gabriel Börner1, Krasnodar Ivancev, Björn Sonesson, Bengt Lindblad, Dennis Griffin, Martin Malina.   

Abstract

PURPOSE: To assess if percutaneous insertion of large-bore sheaths is safe during endovascular repair (EVR) for abdominal aortic aneurysms (AAA).
METHODS: Ninety-five AAA patients undergoing EVR had the endografts implanted percutaneously via 14-F to 20-F sheaths in a prospective nonrandomized study. Vascular sutures were applied bilaterally to the common femoral arteries using a vascular closure device; the sutures were tied after sheath withdrawal. Blood loss, operative time, and length of stay (LOS) were compared to 26 AAA patients undergoing EVR with bilateral femoral cutdowns before the percutaneous technique was available. Follow-up included duplex ultrasonography and clinical examination.
RESULTS: Bilateral percutaneous closure of the femoral arteries was successful in 78 (82%) patients. Fifteen patients required arteriorrhaphy intraoperatively and 2 others within 24 hours. The failure rate was 20%, 0%, 3%, and 7% for the 20-F, 18-F, 16-F, and 14-F introducers, respectively. Blood loss was 400 mL (range 0-1800) in successful cases, 900 mL (range 0-3000) in failures (p<0.0001). One deep infection at the puncture site required thrombectomy and patchplasty; no other late complication occurred. There was no significant difference in operative time, blood loss, and LOS between patients treated with percutaneous EVR and those with primary femoral exposure.
CONCLUSIONS: Percutaneous transfemoral EVR of AAA using large-bore introducer sheaths is safe. More than three quarters of the patients avoid femoral cutdown. Late complications are rare.

Entities:  

Mesh:

Year:  2004        PMID: 15615552     DOI: 10.1583/04-1291MR.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  4 in total

1.  Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter.

Authors:  Rodney P Bensley; Rob Hurks; Zhen Huang; Frank Pomposelli; Allen Hamdan; Mark Wyers; Elliot Chaikof; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2012-02-22       Impact factor: 4.268

2.  A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR.

Authors:  Sergio Petronelli; Maria Teresa Zurlo; Silvia Giambersio; Lucia Danieli; Mariaelena Occhipinti
Journal:  Radiol Med       Date:  2014-04-04       Impact factor: 3.469

Review 3.  Fascia Suture Technique and Suture-mediated Closure Devices: Systematic Review.

Authors:  Georgios Karaolanis; Ioannis D Kostakis; Demetrios Moris; Viktoria-Varvara Palla; Konstantinos G Moulakakis
Journal:  Int J Angiol       Date:  2018-01-22

4.  Percutaneous endovascular abdominal aortic aneurysm repair leads to a reduction in wound complications.

Authors:  C O McDonnell; M V Forlee; J F Dowdall; M-P Colgan; P Madhavan; G D Shanik; D J Moore
Journal:  Ir J Med Sci       Date:  2008-02-02       Impact factor: 1.568

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.