Literature DB >> 15615135

Simultaneous incisor retraction and distal molar movement with microimplant anchorage.

Hyo-Sang Park1, Seong-Min Bae, Hee-Moon Kyung, Jae-Hyun Sung.   

Abstract

AIM: To show how microscrew implants provide orthodontic clinicians with several advantages, eg, the elimination of interarch mechanics for correcting sagittal discrepancies, the reduction of treatment time, the simplification of treatment mechanics, the correction of midline discrepancies without interarch mechanics, and the ability to move entire quadrants rather than individual teeth.
MATERIAL AND METHODS: A step-by- step procedure for inserting microscrews is shown, along with several treated patients, which together demonstrate the mentioned advantages of this technique.
RESULTS: The authors show how microscrews can rescue treatments that have achieved less than ideal occlusion during the course of therapy and offer readers explicit instructions for placing these microimplants.
CONCLUSION: Microscrews offer orthodontic clinicians a minimally intrusive method of intra-arch anchorage that can translate entire quadrants with no untoward reciprocal results that afflict interarch techniques. Clinicians can correct sagittal discrepancies and midline deviations, and gain space for arch-length discrepancies with judicious use of microscrew anchorage.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15615135

Source DB:  PubMed          Journal:  World J Orthod        ISSN: 1530-5678


  4 in total

1.  Case studies on local orthodontic traction by minis-implants before implant rehabilitation.

Authors:  Pei Shen; Wei-Feng Xu; Zhi-Gui Ma; Shan-Yong Zhang; Ying Zhang
Journal:  Int J Clin Exp Med       Date:  2015-05-15

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  Class II correction by maxillary en masse distalization using a completely customized lingual appliance and a novel mini-screw anchorage concept - preliminary results.

Authors:  Frauke Beyling; Elisabeth Klang; Eva Niehoff; Rainer Schwestka-Polly; Hans-Joachim Helms; Dirk Wiechmann
Journal:  Head Face Med       Date:  2021-06-29       Impact factor: 2.151

4.  Biomechanics of extra-alveolar mini-implants.

Authors:  Marcio R Almeida
Journal:  Dental Press J Orthod       Date:  2019-09-05
  4 in total