Literature DB >> 15614881

New fetal cardiac imaging techniques.

Jing Deng1, Charles H Rodeck.   

Abstract

Rapid advances in graphics computing and micro-engineering have offered new techniques for prenatal cardiac imaging. Some of them can be non-invasively applied to both clinical and laboratory settings, including dynamic three-dimensional echocardiography, myocardial Doppler imaging, harmonic ultrasound imaging, and B-flow sonography. With clinical constraints, a few others have been mainly used in laboratories, such as endoscopic ultrasound, magnetic resonance imaging and biomicroscopy. Appropriate use and co-use of these new tools will not only provide unique information for better clinical assessment of fetal cardiac disease but also offer new ways to improved understanding of cardiovascular development and pathogenesis. 2004 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2004        PMID: 15614881     DOI: 10.1002/pd.1066

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  9 in total

1.  Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering.

Authors:  Jin Yamamura; Michael Frisch; Hannes Ecker; Joachim Graessner; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2010-07-30       Impact factor: 5.315

Review 2.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

3.  Applications of 2-dimensional matrix array for 3- and 4-dimensional examination of the fetus: a pictorial essay.

Authors:  Luís F Gonçalves; Jimmy Espinoza; Juan Pedro Kusanovic; Wesley Lee; Jyh Kae Nien; Joaquin Santolaya-Forgas; Giancarlo Mari; Marjorie C Treadwell; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-06       Impact factor: 2.153

4.  A systematic approach to the use of the multiplanar display in evaluation of abnormal vascular connections to the fetal heart using 4-dimensional ultrasonography.

Authors:  Jimmy Espinoza; Sonia S Hassan; Francesca Gotsch; Juan Pedro Kusanovic; Wesley Lee; Offer Erez; Luís F Gonçalves; Mary Lou Schoen; Roberto Romero
Journal:  J Ultrasound Med       Date:  2007-11       Impact factor: 2.153

5.  High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus.

Authors:  Jin Yamamura; Bernhard Schnackenburg; Hendrik Kooijmann; Michael Frisch; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2009-05-09       Impact factor: 5.315

6.  Fetal MRI of the cardiovascular system: role of steady-state free precession sequences for the evaluation of normal and pathological appearances.

Authors:  L Manganaro; S Savelli; M Di Maurizio; A Francioso; F Fierro; A Tomei; F Coratella; L Ballesio; F Ventriglia
Journal:  Radiol Med       Date:  2009-07-01       Impact factor: 3.469

7.  Automated region mask for four-chamber fetal heart biometry.

Authors:  S Vijayalakshmi; N Sriraam; S Suresh; S Muttan
Journal:  J Clin Monit Comput       Date:  2012-10-21       Impact factor: 2.502

8.  Doppler-derived trigger signals for high-frame-rate mouse cardiovascular imaging.

Authors:  Orlando Aristizabal; Jonathan Mamou; Daniel H Turnbull; Jeffrey A Ketterling
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

Review 9.  Translational paradigms in scientific and clinical imaging of cardiac development.

Authors:  Chelsea L Gregg; Jonathan T Butcher
Journal:  Birth Defects Res C Embryo Today       Date:  2013-06
  9 in total