Literature DB >> 156092

Influence of aortic insufficiency on the hemodynamic significance of a coronary artery narrowing.

R L Feldman, W W Nichols, C J Pepine, C R Conti.   

Abstract

The coronary hemodynamic effects of controlled aortic insufficiency (AI) were studied in 10 dogs. Coronary blood flow (CBF), before and during reactive hyperemia (RH) with graded coronary diameter narrowings (CN), aortic (Ao) and left ventricular (LV) pressures (P), and aortic blood flow (AoF) were recorded. Opening an adjustable basket catheter, positioned across the aortic valve, created reversible AI quantitated from phasic AoF. AI was regulated so that mean CBF was similar with or without AI. During AI, heart rate and systolic AoP were unchanged, but diastolic AoP declined 14 mm Hg (mean) and end-diastolic LVP increased 8 mm Hg, both p less than 0.05. With CN greater than or equal to 85%, mean CBF decreased with or without AI. Coronary resistance was similar with or without AI. During AI with no CN, peak RH CBF declined significantly and was similar to peak RH with 70% CN without AI. Furthermore, AI with 60% CN caused additional reduction in peak RH and was similar to peak RH with 80% CN without AI. These data suggest that CBF reserve, exposed during RH, is decreased during AI. With AI, a given CN has coronary hemodynamic properties similar to higher degrees of CN without AI. These results may relate to clinical findings of ischemia in patients with AI and no or moderate CN.

Entities:  

Mesh:

Year:  1979        PMID: 156092     DOI: 10.1161/01.cir.60.2.259

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Anesthetic considerations in acute valvular insufficiency.

Authors:  J L Kramer; S J Thomas
Journal:  Tex Heart Inst J       Date:  1989

Review 2.  Differences in coronary blood flow in aortic regurgitation and systemic arterial hypertension have implications for diastolic blood pressure targets: a systematic review and meta-analysis.

Authors:  Simon W Rabkin
Journal:  Clin Cardiol       Date:  2013-08-27       Impact factor: 2.882

3.  Decreased coronary blood flow velocity in patients with aortic insufficiency but normal coronary arteries: the use of TIMI frame count in aortic insufficiency cases.

Authors:  Abdullah Icli; Halil Mutlu; Turgut Karabag; Halil Kahraman
Journal:  Int J Clin Exp Med       Date:  2015-09-15

4.  Association of aortic stiffness and wave reflections with coronary flow reserve in women without obstructive coronary artery disease: An ancillary study from the National Heart, Lung, and Blood Institute-sponsored Women's Ischemia Syndrome Evaluation (WISE).

Authors:  Wilmer W Nichols; Scott J Denardo; Jonathan B Davidson; Tianyao Huo; C Noel Bairey Merz; Carl J Pepine
Journal:  Am Heart J       Date:  2015-08-28       Impact factor: 4.749

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.