Literature DB >> 15607443

The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis.

A Wieser1, R Debuyst, P Fattibene, A Meghzifene, S Onori, S N Bayankin, B Blackwell, A Brik, A Bugay, V Chumak, B Ciesielski, M Hoshi, H Imata, A Ivannikov, D Ivanov, M Junczewska, C Miyazawa, B Pass, M Penkowski, S Pivovarov, A Romanyukha, L Romanyukha, D Schauer, O Scherbina, K Schultka, A Shames, S Sholom, A Skinner, V Skvortsov, V Stepanenko, E Tielewuhan, S Toyoda, F Trompier.   

Abstract

The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose.

Entities:  

Mesh:

Year:  2005        PMID: 15607443     DOI: 10.1016/j.apradiso.2004.08.027

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  5 in total

1.  Comparison of EPR occupational lifetime external dose assessments for Mayak nuclear workers and film badge dose data.

Authors:  A Wieser; E Vasilenko; P Fattibene; S Bayankin; N El-Faramawy; D Ivanov; P Jacob; V Knyazev; S Onori; M C Pressello; A Romanyukha; M Smetanin; A Ulanovsky
Journal:  Radiat Environ Biophys       Date:  2006-02-03       Impact factor: 1.925

2.  Q-band electron paramagnetic resonance dosimetry in tooth enamel: biopsy procedure and determination of dose detection limit.

Authors:  Alex Romanyukha; François Trompier; Ricardo A Reyes
Journal:  Radiat Environ Biophys       Date:  2014-01-18       Impact factor: 1.925

3.  External dose reconstruction in tooth enamel of Techa riverside residents.

Authors:  E A Shishkina; A Yu Volchkova; Y S Timofeev; P Fattibene; A Wieser; D V Ivanov; V A Krivoschapov; V I Zalyapin; S Della Monaca; V De Coste; M O Degteva; L R Anspaugh
Journal:  Radiat Environ Biophys       Date:  2016-09-06       Impact factor: 1.925

4.  Development of in vivo tooth EPR for individual radiation dose estimation and screening.

Authors:  Benjamin B Williams; Ruhong Dong; Maciej Kmiec; Greg Burke; Eugene Demidenko; David Gladstone; Roberto J Nicolalde; Artur Sucheta; Piotr Lesniewski; Harold M Swartz
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

5.  Camel molar tooth enamel response to gamma rays using EPR spectroscopy.

Authors:  N A El-Faramawy; I El-Somany; A Mansour; A M Maghraby; H Eissa; A Wieser
Journal:  Radiat Environ Biophys       Date:  2017-10-12       Impact factor: 1.925

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.