Literature DB >> 15607439

Differentiation of the observed low frequency (1200MHz) EPR signals in whole human teeth.

Akinori Iwasaki1, Tadeusz Walczak, Oleg Grinberg, Harold M Swartz.   

Abstract

We have determined the properties of the various signals that are observed in vivo so this information can be used to develop procedures for data acquisition and data analysis that will enable the accurate determination of radiation-induced dose with a resolution of 50cGy. Using the 1200MHz in vivo EPR spectrometer and isolated human teeth, we found four types of signals whose properties overlap, but also have some distinct properties that can be exploited to resolve them. The intrinsic background signal in human teeth differs modestly from the radiation-induced signal in g-factor, shape, and power saturation. Random noise from instrumental conditions can be reduced with signal averaging. The microphonic signal varies with the particular experimental setup and has some properties similar to real EPR signals, but is constant if the conditions are not changed. It can be suppressed by improvements in hardware and software, or subtracted.

Entities:  

Mesh:

Year:  2005        PMID: 15607439     DOI: 10.1016/j.apradiso.2004.08.038

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  10 in total

1.  Experimental Procedures for Sensitive and Reproducible In Situ EPR Tooth Dosimetry.

Authors:  Benjamin B Williams; Artur Sucheta; Ruhong Dong; Yasuko Sakata; Akinori Iwasaki; Gregory Burke; Oleg Grinberg; Piotr Lesniewski; Maciej Kmiec; Harold M Swartz
Journal:  Radiat Meas       Date:  2007-07       Impact factor: 1.898

2.  In Vivo EPR For Dosimetry.

Authors:  Harold M Swartz; Greg Burke; M Coey; Eugene Demidenko; Ruhong Dong; Oleg Grinberg; James Hilton; Akinori Iwasaki; Piotr Lesniewski; Maciej Kmiec; Kai-Ming Lo; R Javier Nicolalde; Andres Ruuge; Yasuko Sakata; Artur Sucheta; Tadeusz Walczak; Benjamin B Williams; Chad Mitchell; Alex Romanyukha; David A Schauer
Journal:  Radiat Meas       Date:  2007-07       Impact factor: 1.898

Review 3.  Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry.

Authors:  Céline M Desmet; Philippe Levêque; Bernard Gallez
Journal:  Radiat Prot Dosimetry       Date:  2016-07-29       Impact factor: 0.972

4.  Determination of the Average Native Background and the Light-Induced EPR Signals and their Variation in the Teeth Enamel Based on Large-Scale Survey of the Population.

Authors:  Alexander I Ivannikov; Artem M Khailov; Sergey P Orlenko; Valeri G Skvortsov; Valeri F Stepanenko; Kassym Sh Zhumadilov; Benjamin B Williams; Ann B Flood; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-13       Impact factor: 0.972

5.  A Deployable In Vivo EPR Tooth Dosimeter for Triage After a Radiation Event Involving Large Populations.

Authors:  Benjamin B Williams; Ruhong Dong; Ann Barry Flood; Oleg Grinberg; Maciej Kmiec; Piotr N Lesniewski; Thomas P Matthews; Roberto J Nicolalde; Tim Raynolds; Ildar K Salikhov; Harold M Swartz
Journal:  Radiat Meas       Date:  2011-09-01       Impact factor: 1.898

6.  In vivo EPR tooth dosimetry for triage after a radiation event involving large populations.

Authors:  Benjamin B Williams; Ann Barry Flood; Ildar Salikhov; Kyo Kobayashi; Ruhong Dong; Kevin Rychert; Gaixin Du; Wilson Schreiber; Harold M Swartz
Journal:  Radiat Environ Biophys       Date:  2014-04-08       Impact factor: 1.925

7.  Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.

Authors:  Benjamin B Williams; Ruhong Dong; Roberto J Nicolalde; Thomas P Matthews; David J Gladstone; Eugene Demidenko; Bassem I Zaki; Ildar K Salikhov; Piotr N Lesniewski; Harold M Swartz
Journal:  Int J Radiat Biol       Date:  2011-06-23       Impact factor: 2.694

8.  Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis.

Authors:  Jennifer D Pollock; Benjamin B Williams; Jason W Sidabras; Oleg Grinberg; Ildar Salikhov; Piotr Lesniewski; Maciej Kmiec; Harold M Swartz
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

9.  Development of in vivo tooth EPR for individual radiation dose estimation and screening.

Authors:  Benjamin B Williams; Ruhong Dong; Maciej Kmiec; Greg Burke; Eugene Demidenko; David Gladstone; Roberto J Nicolalde; Artur Sucheta; Piotr Lesniewski; Harold M Swartz
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

10.  Background removal procedure for rapid scan EPR.

Authors:  Mark Tseitlin; Tomasz Czechowski; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2008-10-15       Impact factor: 2.229

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.