Literature DB >> 15598461

Correlation of compartment pressure data from an intraoperative sensing device with postoperative fluoroscopic kinematic results in TKA patients.

Ray C Wasielewski1, Daniel D Galat, Richard D Komistek.   

Abstract

Fluoroscopy has recently been used to analyze postoperative kinematics in total knee arthroplasty (TKA). These analyses have reported varying results even in patients with similar implant design. In addition, patterns of wear in retrieved tibial polyethylene inserts of similar design have been found to vary substantially. These findings suggest that surgical technique, especially soft tissue balancing, may play a role in postoperative kinematics and implant failure. Accurate soft-tissue balancing is hypothesized to result in similar pressures within the medial and lateral compartments of the knee. However, a method of easily measuring these pressures at TKA has not been developed. In the present study, 32 patients were implanted with a mobile-bearing LCS TKA utilizing the balanced gap technique. An electronic pressure sensor, developed specifically to record pressure magnitude and distribution in the medial and lateral compartments, was incorporated into the implant trials. The knee was then passively taken through a range of motion while pressure data was recorded via computer. Postoperatively, 16 patients underwent active fluoroscopic kinematic analysis to assess for condylar liftoff and femorotibial translation. We found that abnormal compartment pressures and distributions as recorded by the intraoperative pressure sensor were correlated with inappropriate or paradoxical postoperative kinematics. In addition, subjects having similar pressures in both compartments throughout a range of motion did not experience condylar liftoff values greater than 1.0 mm. These data suggest that surgical technique influences the magnitude and distribution of forces at the articulation, postoperative kinematics, and likely, implant longevity.

Entities:  

Mesh:

Year:  2005        PMID: 15598461     DOI: 10.1016/j.jbiomech.2004.02.040

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Measurement of joint gap load in patella everted and reset position during total knee arthroplasty.

Authors:  Nobuyuki Yoshino; Nobuyoshi Watanabe; Yoshinobu Watanabe; Yukihisa Fukuda; Shinro Takai
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-08       Impact factor: 4.342

2.  Patient-related factors influence stiffness of the soft tissue complex during intraoperative gap balancing in cruciate-retaining total knee arthroplasty.

Authors:  P J C Heesterbeek; N Haffner; A B Wymenga; J Stifter; P Ritschl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-15       Impact factor: 4.342

3.  How are we addressing ligament balance in TKA? A literature review of revision etiology and technological advancement.

Authors:  Tyler Smith; Leah Elson; Christopher Anderson; William Leone
Journal:  J Clin Orthop Trauma       Date:  2016-08-03

4.  Algorithmic pie-crusting of the medial collateral ligament guided by sensing technology affects the use of constrained inserts during total knee arthroplasty.

Authors:  Spencer Amundsen; Yuo-Yu Lee; Alejandro González Della Valle
Journal:  Int Orthop       Date:  2017-02-10       Impact factor: 3.075

5.  Design and cadaveric validation of a novel device to quantify knee stability during total knee arthroplasty.

Authors:  Robert A Siston; Thomas L Maack; Erin E Hutter; Matthew D Beal; Ajit M W Chaudhari
Journal:  J Biomech Eng       Date:  2012-11       Impact factor: 2.097

Review 6.  Intraoperative load-sensing drives the level of constraint in primary total knee arthroplasty: Surgical technique and review of the literature.

Authors:  Salvatore Risitano; Brian Karamian; Pier Francesco Indelli
Journal:  J Clin Orthop Trauma       Date:  2017-06-02

7.  No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty.

Authors:  Satoshi Hamai; Hiromasa Miura; Ken Okazaki; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-17       Impact factor: 4.342

Review 8.  ["Ligament balancing" and varus deformity in total knee arthroplasty].

Authors:  A Claus; H-P Scharf
Journal:  Orthopade       Date:  2007-07       Impact factor: 1.087

9.  Development of a pneumatic tensioning device for gap measurement during total knee arthroplasty.

Authors:  Dai-Soon Kwak; Chae-Gwan Kong; Seung-Ho Han; Dong-Hyun Kim; Yong In
Journal:  Clin Orthop Surg       Date:  2012-08-14

10.  The relevance of ligament balancing in total knee arthroplasty: how important is it? A systematic review of the literature.

Authors:  Sina Babazadeh; James D Stoney; Keith Lim; Peter F M Choong
Journal:  Orthop Rev (Pavia)       Date:  2009-10-10
View more