Literature DB >> 15598459

A novel method for in vivo knee prosthesis wear measurement.

A Short1, H S Gill, B Marks, J C Waite, C F Kellett, A J Price, J J O'Connor, D W Murray.   

Abstract

Wear remains an important cause of failure in knee replacement. Of the current methods of early performance assessment or prediction, simulators have been un-physiological, single X-ray film analyses remain limited by accuracy and retrieval and survival methods have a prohibitive time scale. An accurate method is needed to allow a timely assessment of polyethylene component wear in vivo, when a new design is introduced, in order to predict likely outcome. We present a new method for measuring wear in vivo that we believe will allow this prediction of long-term wear. X-ray film pairs were taken of implanted prosthetic metal components. When the X-ray system was calibrated, projections of the appropriate Computer Aided Design (CAD) model could be matched to the shapes on the scanned X-ray films to find component positions. Interpenetration of the metal femoral component into the polyethylene component could then be established and represents our estimate of "wear". This method was used to measure in vivo prosthesis wear to an accuracy of 0.11 mm.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15598459     DOI: 10.1016/j.jbiomech.2004.02.023

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

2.  CORR Insights®: Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA.

Authors:  Robert H Hopper
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

3.  Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA.

Authors:  Matthew G Teeter; Jacob Wihlidal; Richard W McCalden; Xunhua Yuan; Steven J MacDonald; Brent A Lanting; Douglas D Naudie
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

4.  Cross-linked versus conventional polyethylene for total knee arthroplasty: a meta-analysis.

Authors:  Bin-feng Yu; Guo-jing Yang; Wei-liang Wang; Lei Zhang; Xi-peng Lin
Journal:  J Orthop Surg Res       Date:  2016-03-30       Impact factor: 2.359

5.  Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement.

Authors:  Priyanka Ghosh; Hasan R Mohammad; Benjamin Martin; Stefano Campi; David W Murray; Stephen J Mellon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-09-17       Impact factor: 4.342

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.