Literature DB >> 15597017

Protocol optimization of multidetector computed tomography colonography using pig colonic phantoms.

Hyung Jin Won1, Byung Ihn Choi, Se Hyung Kim, Young Il Kim, Byung Jae Youn, Joon Koo Han.   

Abstract

OBJECTIVE: The introduction of multidetector computed tomography (CT) increases the possibility of enhanced polyp detection using CT colonography. The effects of collimation and tube currents on polyp detection were investigated in pig colonic phantoms to determine the optimal scanning parameters.
MATERIALS AND METHODS: Twenty pig colons were prepared, and polyps with diameters ranging from 3 mm to 15 mm were created and randomly distributed. There was a total of 60 polyps; 20 polyps were 3 to 5 mm in size, 21 polyps 6 to 9 mm, and 19 polyps 10 to 15 mm. The pig colons were sealed, distended with air, submerged in water, and were arranged to mimic the in vivo arrangement. CT was performed using a 4-row multidetector CT scanner with collimations of 1, 2.5, and 5 mm, a pitch of 1.75, and mA of 100. A low-dose protocol (mA of 50) was added with a collimation of 1 mm. Two blinded observers independently analyzed the datasets.
RESULTS: : The overall sensitivities of CT colonography were 94.2% with 1-mm collimation, 80% with 2.5-mm collimation, and 75% with 5-mm collimation. Considering the sensitivity of each protocol for the size of the polyps, the 1-mm collimation protocol had a sensitivity of 87.5% for 3- to 5-mm polyps, 95.2% sensitivity for 6- to 9-mm polyps, and 100% sensitivity for 10- to 15-mm polyps; the 2.5-mm protocol had 50%, 92.9%, and 97.4% sensitivities, respectively; and the 5-mm protocol had 47.5%, 88.1%, and 89.5% sensitivities, respectively, for the respective polyp size group. A significant difference in sensitivity among the protocols was present in the 3- to 5-mm polyps. No significant difference was seen between the standard- and the low-dose protocols.
CONCLUSIONS: The sensitivity of multidetector CT colonography for detecting polyps larger than 5 mm is robust over a range of collimation in pig colonic phantoms. However, reliable detection of polyps 5 mm or smaller requires a 1-mm collimation. Sensitivity is not influenced by lowering the mA from 100 to 50.

Entities:  

Mesh:

Year:  2005        PMID: 15597017

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Computed Tomographic (CT) Colonography for Colorectal Cancer Screening: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-09-01

2.  The change in ratio of convex and concave lung volume in adolescent idiopathic scoliosis: a 3D CT scan based cross sectional study of effect of severity of curve on convex and concave lung volumes in 99 cases.

Authors:  Eun Mi Chun; Seung Woo Suh; Hitesh N Modi; Eun Young Kang; Suk Joo Hong; Hae-Ryong Song
Journal:  Eur Spine J       Date:  2007-10-03       Impact factor: 3.134

3.  Evaluation of postoperative change in lung volume in adolescent idiopathic scoliosis: Measured by computed tomography.

Authors:  Dong Kyu Lee; Eun Mi Chun; Seung Woo Suh; Jae Hyuk Yang; Sung Shine Shim
Journal:  Indian J Orthop       Date:  2014-07       Impact factor: 1.251

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.