Literature DB >> 15595992

Automated detection of malaria by means of the haematology analyser Coulter GEN.S.

C Fourcade1, M J C Casbas, H Belaouni, J J D Gonzalez, P J J Garcia, M A E Pepio.   

Abstract

The haematology analysers Coulter(R) GEN.S(TM) and LH(TM) give a set of data--'positional parameters'--which define each WBC population by mean of index values, the mean and the standard deviation (SD) of volume, conductivity and scatter, used to identify the WBC populations. These parameters were analysed in patients investigated for suspicion of malaria, in order to show a difference between malaria negative and malaria positive patients and to use it for malaria detection. The six parameters exhibiting a significant difference between the two groups were submitted to a ROC analysis, which showed both sensitivity >90% and specificity >60% for two parameters, lymphocyte and monocyte SDs of volumes. A discriminator combining the two parameters showed a sensitivity of 96.9% and a specificity of 82.5%. The cut off of the discriminative value was calculated. Because of the good stability and reproducibility of the parameters selected, the test can be used in order to detect patients having a high probability to be malaria positive and to pay particular attention to these blood smears. For more extensive diagnostic use, a standard control procedure of the positional parameters should be introduced.

Entities:  

Mesh:

Year:  2004        PMID: 15595992     DOI: 10.1111/j.1365-2257.2004.00648.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  4 in total

1.  Application of Sysmex XN-Series Automated Haematology Analyser in the Rapid Detection of Malaria.

Authors:  Aparna Ningombam; Abhirup Sarkar; Shreyam Acharya; Anita Chopra; Kundan Kumar; Arulselvi Subramanian
Journal:  Indian J Hematol Blood Transfus       Date:  2020-04-03       Impact factor: 0.900

2.  Design of malaria diagnostic criteria for the Sysmex XE-2100 hematology analyzer.

Authors:  Germán Campuzano-Zuluaga; Gonzalo Alvarez-Sánchez; Gloria Elcy Escobar-Gallo; Luz Marina Valencia-Zuluaga; Alexandra Marcela Ríos-Orrego; Adriana Pabón-Vidal; Andrés Felipe Miranda-Arboleda; Silvia Blair-Trujillo; Germán Campuzano-Maya
Journal:  Am J Trop Med Hyg       Date:  2010-03       Impact factor: 2.345

Review 3.  Automated haematology analysis to diagnose malaria.

Authors:  Germán Campuzano-Zuluaga; Thomas Hänscheid; Martin P Grobusch
Journal:  Malar J       Date:  2010-11-30       Impact factor: 2.979

4.  Incidental Identification of Plasmodium vivax During Routine Complete Blood Count Analysis Using the UniCel DxH 800.

Authors:  Soyoung Shin; Sun Hee Park; Joonhong Park
Journal:  Ann Lab Med       Date:  2018-03       Impact factor: 3.464

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.