Literature DB >> 15595704

Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failures?

Björn Johansson1, Tomas Bäck, Jan-Michael Hirsch.   

Abstract

BACKGROUND: Bone grafts are frequently used to enable the placement of dental implants in atrophied jaws. The biomechanical properties of bone grafts used in one- or two-stage implant procedures (in comparison with the use of nongrafted bone) are not well known.
PURPOSE: The purpose of this study was (1) to measure cutting torques during the placement of self-tapping dental implants in nongrafted bone and in bone grafts, either as blocks or in a milled particulate form, in patients undergoing implant treatment in an edentulous maxilla and (2) to identify implants with reduced initial stability and to correlate these findings with a clinical classification of jawbone quality.
MATERIALS AND METHODS: The study included 40 consecutive patients with edentulous maxillas, 27 of whom were subjected to bone grafting prior to or in conjunction with implant placement (grafting group) and 13 of whom received implants without grafting (nongrafted group). Grafted bone from the iliac crest bone was used (1) as onlay blocks, (2) as maxillary sinus inlay blocks, or (3) in particulate form in the maxillary sinus. Implants were placed after 6 to 7 months of healing, except in the maxillary sinus inlay blocks, where implants were placed simultaneously. Cutting torque values were obtained from 113 grafted implant sites and from 109 nongrafted implant sites.
RESULTS: Significantly lower cutting torque values were assessed in grafted regions than in nongrafted regions, irrespective of grafting technique. Lower values were also seen for implants placed in block grafts after 6 months when compared to other grafting techniques used. The cutting torque values revealed an inverse linear relation to the Lekholm and Zarb bone quality index.
CONCLUSION: The cutting torque values correlated well with the Lekholm and Zarb index of bone quality. Significantly lower cutting torque values were seen in grafted bone than in nongrafted bone.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15595704     DOI: 10.1111/j.1708-8208.2004.tb00022.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Histological and histomorphometric aspects of continual intermittent parathyroid hormone administration on osseointegration in osteoporosis rabbit model.

Authors:  Yoshifumi Oki; Kazuya Doi; Reiko Kobatake; Yusuke Makihara; Koji Morita; Takayasu Kubo; Kazuhiro Tsuga
Journal:  PLoS One       Date:  2022-06-08       Impact factor: 3.752

2.  Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study.

Authors:  Hiroshi Oue; Kazuya Doi; Yoshifumi Oki; Yusuke Makihara; Takayasu Kubo; Vittoria Perrotti; Adriano Piattelli; Yasumasa Akagawa; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2015-03-18

3.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

Review 4.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

5.  Application of low-crystalline carbonate apatite granules in 2-stage sinus floor augmentation: a prospective clinical trial and histomorphometric evaluation.

Authors:  Takayuki Nakagawa; Keiko Kudoh; Naoyuki Fukuda; Shohei Kasugai; Noriko Tachikawa; Kiyoshi Koyano; Yasuyuki Matsushita; Masanori Sasaki; Kunio Ishikawa; Youji Miyamoto
Journal:  J Periodontal Implant Sci       Date:  2019-10-09       Impact factor: 2.614

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.