Infection rates in standard vs. hydrogel coated ventricular catheters.

Anthony M Kaufmann1, Tara Lye, Gary Redekop, Angela Brevner, Mark Hamilton, Michelle Kozey, David Easton.   

Abstract

BACKGROUND: Infection related to external ventricular drain (EVD) use is a common neurosurgical complication. Modified catheters with a hydrophilic surface may impede bacterial adherence and thereby reduce catheter related cerebrospinal fluid (CSF) infection.
METHODS: A prospective randomized clinical trial compared the occurrence of CSF infection related to use of either standard silastic or hydrogel coated EVD catheters (Bioglide, Medtronic). Enrolment was available to all adult neurosurgery patients undergoing placement of a first EVD, at three university centers. The catheters were presoaked in a low concentration of bacitracin solution for 5-10 minutes prior to insertion. Bacterial infection was defined by heavy growth in a single CSF sample or light/medium growth in two consecutive samples. A secondary analysis was also conducted for "probable" CSF infection, including patients started on antibiotics after light/medium growth in a single CSF sample. Statistical analyses included Kaplan-Meier survival curve estimates accompanied by Log Rank and Breslow tests.
RESULTS: There were 158 randomized patients available to assess for EVD related infection of CSF. The two study groups had similar clinical characteristics including average duration of EVD use (8 +/- 4 days). Definite CSF infection occurred in seven and probable infection in another six (8% total). Infection incidence rose steadily from day 2 (1%) to day 11 (11%). There was no difference of daily occurrence of EVD infection between the two catheter types.
CONCLUSIONS: Infection remains a common hazard in the use of EVD, and we found no reduction of infection using the hydrogel-coated catheters when presoaked in low concentration bacitracin solution.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15595257     DOI: 10.1017/s0317167100003723

Source DB:  PubMed          Journal:  Can J Neurol Sci        ISSN: 0317-1671            Impact factor:   2.104


  7 in total

Review 1.  Strategies to decrease the risk of ventricular catheter infections: a review of the evidence.

Authors:  Maya A Babu; Robin Patel; W Richard Marsh; Eelco F M Wijdicks
Journal:  Neurocrit Care       Date:  2012-02       Impact factor: 3.210

Review 2.  External ventricular drainage for intraventricular hemorrhage.

Authors:  Mahua Dey; Jennifer Jaffe; Agnieszka Stadnik; Issam A Awad
Journal:  Curr Neurol Neurosci Rep       Date:  2012-02       Impact factor: 5.081

3.  Reduced cell attachment to poly(2-hydroxyethyl methacrylate)-coated ventricular catheters in vitro.

Authors:  Brian W Hanak; Chia-Yun Hsieh; William Donaldson; Samuel R Browd; Kenneth K S Lau; William Shain
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-06-20       Impact factor: 3.368

4.  Bleeding and infection with external ventricular drainage: a systematic review in comparison with adjudicated adverse events in the ongoing Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage Phase III (CLEAR-III IHV) trial.

Authors:  Mahua Dey; Agnieszka Stadnik; Fady Riad; Lingjiao Zhang; Nichol McBee; Carlos Kase; J Ricardo Carhuapoma; Malathi Ram; Karen Lane; Noeleen Ostapkovich; Francois Aldrich; Charlene Aldrich; Jack Jallo; Ken Butcher; Ryan Snider; Daniel Hanley; Wendy Ziai; Issam A Awad
Journal:  Neurosurgery       Date:  2015-03       Impact factor: 4.654

5.  Protective effect of rifampicin and clindamycin impregnated devices against Staphylococcus spp. infection after cerebrospinal fluid diversion procedures.

Authors:  Raquel Gutiérrez-González; Gregorio R Boto; Cristina Fernández-Pérez; Náyade del Prado
Journal:  BMC Neurol       Date:  2010-10-12       Impact factor: 2.474

6.  Central nervous system infections in the neurointensive care unit.

Authors:  Fred Rincon; Neeraj Badjatia
Journal:  Curr Treat Options Neurol       Date:  2006-03       Impact factor: 3.972

7.  Hydrogel-coated ventricular catheters for high-risk patients receiving ventricular peritoneum shunt.

Authors:  Hao Xu; Yimin Huang; Wei Jiao; Wei Sun; Ran Li; Jiaqing Li; Ting Lei
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889