| Literature DB >> 15593397 |
Chun-xiu Pan1, Xiu-zhu Xu, Hong-mei He, Xiao-jun Cai, Xue-jun Zhang.
Abstract
The cis and trans isomers separation of 2-butene-1,4-diol and lafutidine were studied by HPLC on two kinds of chiral columns: (S,S)-Whelk-O 1 and ChiraSpher. The isomers of 2-butene-1,4-diol can be separated on both chiral columns while the isomers of lafutidine can only be resolved on ChiraSpher column. The influence of different type and amount of mobile phase modifier on the isomers separation was extensively studied. The resolution of cis and trans isomers of 2-butene-1,4-diol was 2.61 on (S,S)-Whelk-O 1 column with hexane-ethanol (97:3, v/v) as the mobile phase. The resolution of lafutidine was 1.89 on ChiraSpher column with hexane-ethanol-THF-diethylamine (92:3:5:0.1, v/v/v/v) as the mobile phase. LC-MS methods were developed to identify the isomer peaks.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15593397 PMCID: PMC1390763 DOI: 10.1631/jzus.2005.B0074
Source DB: PubMed Journal: J Zhejiang Univ Sci B ISSN: 1673-1581 Impact factor: 3.066