An evaluation of the mini-Wright peak flow meter.

W H Perks, I P Tams, D A Thompson, K Prowse.   

Abstract

The mini-Wright peak flow meter (MPFM) has been evaluated, and the results obtained from it show a strong positive correlation (r=0.970) with the Wright's peak flow meter (PFM). MPFM measurements, however, were biased to be about 38 1/min higher than PFM measurements (95% confidence limits 31.01/min to 45.01/min). Between instrument variation was found (F--ratio 3.67 with 9 and 81 degrees of freedom: P less than 0.001). In practice this did not appreciably affect individual measurements greatly as 95% confidence limits on any individual measurements were increased from +/-24 1/min to +/-27 1/min. There was no significant day-to-day variability in measurements obtained with individual instruments. The MPFM is a pocket-sized, simple, cheap, and robust instrument for following changes in ventilatory function. In clinical trails and surveys, however, both the bias in favour of the MPFM compared to the PFM and inter-machine variation must be taken into account. As the manufacturers have altered the scale to remove the bias since this study was performed, it will be important to know whether the original or the modified meter is being used in future studies.

Mesh:

Year:  1979        PMID: 155892      PMCID: PMC471012          DOI: 10.1136/thx.34.1.79

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  6 in total

1.  Maximum forced expiratory flow rate as a measure of ventilatory capacity: with a description of a new portable instrument for measuring it.

Authors:  B M WRIGHT; C B McKERROW
Journal:  Br Med J       Date:  1959-11-21

2.  On observing patterns of airflow obstruction in chronic asthma.

Authors:  M Turner-Warwick
Journal:  Br J Dis Chest       Date:  1977-04

3.  Trial of disodium cromoglycate in bronchial asthma.

Authors:  D G Robertson; S W Epstein; D A Warrell
Journal:  Br Med J       Date:  1969-03-01

4.  Pulmonary monitor for assessment of airways obstruction.

Authors:  S P Haydu; T T Chapman; D T Hughes
Journal:  Lancet       Date:  1976-12-04       Impact factor: 79.321

5.  Practical pulmonary function testing.

Authors:  F G Ward
Journal:  J Soc Occup Med       Date:  1977-10

6.  Comparison of peak flow gauge and peak flow meter.

Authors:  A Bhoomkar; S Davies; M Greary; E Hills
Journal:  Thorax       Date:  1975-04       Impact factor: 9.139

  6 in total
  13 in total

1.  The accuracy of portable peak flow meters.

Authors:  M R Miller; S A Dickinson; D J Hitchings
Journal:  Thorax       Date:  1992-11       Impact factor: 9.139

2.  Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.

Authors:  H G Oldham; M M Bevan; M McDermott
Journal:  Thorax       Date:  1979-12       Impact factor: 9.139

3.  Peak expiratory flow as a surrogate for health related quality of life in chronic obstructive pulmonary disease: a preliminary cross sectional study.

Authors:  D O Obaseki; M O Akanbi; C C Onyedum; O B Ozoh; J Jumbo; A A Akor; G E Erhabor
Journal:  Ghana Med J       Date:  2014-06

4.  Discrepancy between standard and low range mini Wright peak flow meters.

Authors:  T P Usherwood; J H Barber
Journal:  Br Med J (Clin Res Ed)       Date:  1986-02-22

5.  Home-monitoring of peak expiratory flow rate using mini-Wright peak flow meter in diagnosis of asthma.

Authors:  J G Prior; G M Cochrane
Journal:  J R Soc Med       Date:  1980-10       Impact factor: 5.344

6.  Tiaramide--a new oral drug for the treatment of asthma.

Authors:  K E Berkin; J W Kerr
Journal:  Br J Clin Pharmacol       Date:  1982-10       Impact factor: 4.335

7.  Effectiveness of routine self monitoring of peak flow in patients with asthma. Grampian Asthma Study of Integrated Care (GRASSIC).

Authors: 
Journal:  BMJ       Date:  1994-02-26

8.  Accuracy of mini peak flow meters in indicating changes in lung function in children with asthma.

Authors:  P D Sly; P Cahill; K Willet; P Burton
Journal:  BMJ       Date:  1994-02-26

9.  Comparison of normal and asthmatic circadian rhythms in peak expiratory flow rate.

Authors:  M R Hetzel; T J Clark
Journal:  Thorax       Date:  1980-10       Impact factor: 9.139

10.  Normal Peak Expiratory Flow Rate of School Children in Jabalpur, Madhya Pradesh.

Authors:  Keerthi Kumaran; Avyact Agrawal
Journal:  Indian J Pediatr       Date:  2017-04-08       Impact factor: 1.967

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.