Literature DB >> 15588592

Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications.

Kullervo Hynynen1, Nathan McDannold, Nickolai A Sheikov, Ferenc A Jolesz, Natalia Vykhodtseva.   

Abstract

The purpose of this study was to test the hypothesis that burst ultrasound in the presence of an ultrasound contrast agent can disrupt the blood-brain barrier (BBB) with acoustic parameters suitable for completely noninvasive exposure through the skull. The 10-ms exposures were targeted in the brains of 22 rabbits with a frequency of 690 kHz, a repetition frequency of 1 Hz, and peak rarefactional pressure amplitudes up to 3.1 MPa. The total exposure (sonication) time was 20 s. Prior to each sonication, a bolus of ultrasound contrast agent was injected intravenously. Contrast-enhanced MR images were obtained after the sonications to detect localized BBB disruption via local enhancement in the brain. Brain sections were stained with H&E, TUNEL, and vanadium acid fuchsin (VAF)-toluidine blue staining. In addition, horseradish peroxidase (HRP) was injected into four rabbits prior to sonications and transmission electron microscopy was performed. The MRI contrast enhancement demonstrated BBB disruption at pressure amplitudes starting at 0.4 MPa with approximately 50%; at 0.8 MPa, 90%; and at 1.4 MPa, 100% of the sonicated locations showed enhancement. The histology findings following 4 h survival indicated that brain tissue necrosis was induced in approximately 70-80% of the sonicated locations at a pressure amplitude level of 2.3 MPa or higher. At lower pressure amplitudes, however, small areas of erythrocyte extravasation were seen. The electron microscopy findings demonstrated HRP passage through vessel walls via both transendothelial and paraendothelial routes. These results demonstrate that completely noninvasive focal disruption of the BBB is possible.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15588592     DOI: 10.1016/j.neuroimage.2004.06.046

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  210 in total

1.  Ultrasound-enhanced drug transport and distribution in the brain.

Authors:  Ying Liu; Sumit Paliwal; Krystof S Bankiewicz; John R Bringas; Gill Heart; Samir Mitragotri; Mark R Prausnitz
Journal:  AAPS PharmSciTech       Date:  2010-06-08       Impact factor: 3.246

2.  Combination treatment with rt-PA is more effective than rt-PA alone in an in vitro human clot model.

Authors:  Jason M Meunier; Christy K Holland; Tyrone M Porter; Christopher J Lindsell; George J Shaw
Journal:  Curr Neurovasc Res       Date:  2011-11       Impact factor: 1.990

3.  Blood-brain barrier: real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Radiology       Date:  2012-02-13       Impact factor: 11.105

Review 4.  Ultrasound enhanced drug delivery to the brain and central nervous system.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

5.  Neuronavigation-guided focused ultrasound-induced blood-brain barrier opening: a preliminary study in swine.

Authors:  K-C Wei; H-C Tsai; Y-J Lu; H-W Yang; M-Y Hua; M-F Wu; P-Y Chen; C-Y Huang; T-C Yen; H-L Liu
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

6.  Reorganization of gap junctions after focused ultrasound blood-brain barrier opening in the rat brain.

Authors:  Angelika Alonso; Eileen Reinz; Jürgen W Jenne; Marc Fatar; Hannah Schmidt-Glenewinkel; Michael G Hennerici; Stephen Meairs
Journal:  J Cereb Blood Flow Metab       Date:  2010-03-24       Impact factor: 6.200

7.  Mechanisms of the increase in the permeability of the blood-tumor barrier obtained by combining low-frequency ultrasound irradiation with small-dose bradykinin.

Authors:  Chun-yi Xia; Zhen Zhang; Yi-xue Xue; Ping Wang; Yun-hui Liu
Journal:  J Neurooncol       Date:  2009-02-22       Impact factor: 4.130

Review 8.  Magnetic resonance-guided focused ultrasound: a new technology for clinical neurosciences.

Authors:  Ferenc A Jolesz; Nathan J McDannold
Journal:  Neurol Clin       Date:  2013-11-08       Impact factor: 3.806

9.  Assessment of temporary cerebral effects induced by focused ultrasound with optical coherence tomography angiography.

Authors:  Meng-Tsan Tsai; Jia-Wei Zhang; Kuo-Chen Wei; Chih-Kuang Yeh; Hao-Li Liu
Journal:  Biomed Opt Express       Date:  2018-01-08       Impact factor: 3.732

10.  Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

Authors:  Ali Mohammadabadi; Ruby N Huynh; Aniket S Wadajkar; Rena G Lapidus; Anthony J Kim; Christopher B Raub; Victor Frenkel
Journal:  Phys Med Biol       Date:  2020-06-22       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.