| Literature DB >> 15587721 |
Cheng-Tang Pan1, Chi-Hui Chien, Chi-Chang Hsieh.
Abstract
A batch-fabricated microball lens array not only provides accurate coupling distances but also replaces traditional components such as aspheric lenses and expensive graded-index lenses without sacrificing performance and reduces assembly cost. The results of extensive experiments show a critical aspect ratio of approximately 0.3. That is, when the aspect ratio is larger than 0.3, the final shape of a reflowed lens changes to that of a microball rather than of a mushroom. Using a laser with a 633-nm wavelength yields an optimum coupling distance of approximately 8 microm with an insertion loss below -1.3 dB (coupling efficiency, approximately 73%).Entities:
Year: 2004 PMID: 15587721 DOI: 10.1364/ao.43.005939
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980