Midterm results of endoluminal stent grafting of the thoracic aorta.

Laurence Destrieux-Garnier1, Stéphan Haulon, Serge Willoteaux, Cristophe Decoene, Claire Mounier-Vehier, Pascal Halna, Julien Gaudric, Thomas Modine, Jean-Paul Beregi, Mohamad Koussa.   

Abstract

The purpose of this study was to evaluate the overall outcome of repair of thoracic aortic lesions with endoluminal grafts. Patients were studied prospectively following the implantation of a thoracic endovascular device. Preoperative imaging was performed by helical computed tomography (CT), angiography, transesophageal ultrasonography, or magnetic resonance imaging. Procedures were performed in an endovascular surgical suite under general anesthesia. All patients were evaluated with CT and chest radiography at discharge and at 1, 6, and 12 months. From December 1999 to November 2001, thirty-two patients were enrolled in the study (mean age 62 years; 20 male and 12 female patients). Seventeen patients had dissections, five patients had ruptured aortic ulcer, five patients had traumatic ruptures, three patients had atherosclerotic aneurysms, and two patients had pseudoaneurysms. An American Society of Anesthesiology score of III or IV was evaluated in 22 (69%) patients. The procedure was performed under emergency conditions in 11 cases. All prostheses were implanted successfully. There were no conversions. Three patients (9%) presented with a neurologic event following the implantation procedure, which was lethal in one case (hemorrhagic stroke). Two other patients died during early follow-up of myocardial infarction and multiorgan failure. The early death rate was 9%. The mean follow-up was 13.5 months. During follow-up, the maximal diameter of the aorta shrunk (> or = 5 mm) in 9 (28%) patients, remained stable in 17 (53%) patients, and increased (> or = 5 mm) in 6 (19%) patients. All patients presenting with an increased diameter were initially treated for dissections. A type 1 endoleak was diagnosed on the discharge CT scan in one patient. It sealed spontaneously thereafter. A type 3 endoleak was diagnosed 3 months after the procedure in one patient. A complementary stent graft was implanted in two patients presenting with a dissection with persistent patent false lumen and aortic enlargement. Three patients died during follow-up (two aneurysm-related and one aneurysm-unrelated death). The morbidity and mortality rates reported in our series related to the preoperative morbid conditions of the patients treated. Thoracic aorta endografting is an alternative to open surgery in this subset of patients.

Entities:  

Mesh:

Year:  2004        PMID: 15586526     DOI: 10.1258/rsmvasc.12.3.179

Source DB:  PubMed          Journal:  Vascular        ISSN: 1708-5381            Impact factor:   1.285


  3 in total

1.  Endoluminal stenting of mycotic saccular aneurysm at the aortic arch.

Authors:  Ufuk Alpagut; Murat Ugurlucan; Eylul Kafali; Benguhan Surmen; Omer Ali Sayin; Koray Guven; Enver Dayioglu; Izzet Rozanes; Ertan Onursal
Journal:  Tex Heart Inst J       Date:  2006

Review 2.  Endovascular stent-graft placement for vascular failure of the thoracic aorta.

Authors:  Yoshihiko Kurimoto; Kiyofumi Morishita; Yasufumi Asai
Journal:  Vasc Health Risk Manag       Date:  2006

3.  Right procedure, wrong organ, an unusual case report of aortic trauma in a multiple injured patient.

Authors:  Aristotelis P Mitsos; Jonathan Chantler; Evangelos Konstantinou; Theofanis Fotis; Ekaterini Lambrinou; Ramon Uberoi; Richard Stacey; James V Byrne
Journal:  Cases J       Date:  2009-06-05
  3 in total