Literature DB >> 15585021

Correlation between the extent of platelet activation in platelet concentrates and in vitro and in vivo parameters.

M J Dijkstra-Tiekstra1, R N I Pietersz, P C Huijgens.   

Abstract

BACKGROUND AND OBJECTIVES: Platelet activation, which is necessary to stop bleeding, also occurs in vitro during the storage of platelet concentrates (PCs). However, it is unknown whether in vitro-activated platelets are able to reduce blood loss in the patient. We studied correlations between platelet activation in PCs and in vitro parameters (pH, platelet count, swirling effect, storage time). In addition, we studied the correlation between platelet activation and in vivo parameters [the volume of thorax drain fluid as a measure of blood loss, platelet count, international normalized ratio (INR), and activated partial thrombin time (APTT)] in a clinical pilot study.
MATERIALS AND METHODS: White blood cell-reduced PCs prepared from five buffy coats and one plasma unit (n = 55; storage time: median, 5 days; range, 2-12 days) were sampled. Platelet activation (CD62p, CD63, CD42b), as measured by flow cytometry, pH, platelet count, swirling effect and storage time, was determined. For the in vivo pilot study, PCs (n = 21) stored for 2-7 days were also checked for the above parameters and transfused into patients (n = 21) immediately after coronary artery bypass graft surgery. The volume of thorax drain fluid was measured for up to 12 h after surgery, and the platelet count, INR and APTT were measured < 1 h and 16-24 h postsurgery.
RESULTS: A good correlation (r2 > 0.5) was observed between CD62p and CD63, between CD62p and CD42b, between CD62p or CD63 and pH and between CD62p or CD63 and swirling effect. Also, a significant increase in platelet activation was observed for PCs stored for > or = 8 days (mean +/- standard deviation: CD62p, 41.6 +/- 30.7; CD63, 23.8 +/- 18.6), compared to PCs stored for 2-7 days (mean +/- standard deviation: CD62p, 12.3 +/- 4.8; CD63, 10.4 +/- 3.6). No correlation (r2 < or = 0.1) was observed between platelet activation and the in vivo parameters.
CONCLUSIONS: Although a correlation between platelet activation and in vitro parameters was observed, no correlation was found between platelet activation and in vivo parameters. Possible explanations for this are a too low variance in platelet activation in transfused PCs, and too small a number of patients.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15585021     DOI: 10.1111/j.1423-0410.2004.00573.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  4 in total

1.  UVC Irradiation for Pathogen Reduction of Platelet Concentrates and Plasma.

Authors:  Axel Seltsam; Thomas H Müller
Journal:  Transfus Med Hemother       Date:  2011-01-22       Impact factor: 3.747

Review 2.  Novel and unexpected clearance mechanisms for cold platelets.

Authors:  Viktoria Rumjantseva; Karin M Hoffmeister
Journal:  Transfus Apher Sci       Date:  2009-11-20       Impact factor: 1.764

3.  Platelet responses to agonists in a cohort of highly characterised platelet donors are consistent over time.

Authors:  S F Garner; A Furnell; B C Kahan; C I Jones; A Attwood; P Harrison; A M Kelly; A H Goodall; R Cardigan; W H Ouwehand
Journal:  Vox Sang       Date:  2016-12-21       Impact factor: 2.144

4.  Bispecific Antibody Inhalation Therapy for Redirecting Stem Cells from the Lungs to Repair Heart Injury.

Authors:  Mengrui Liu; Halle Lutz; Dashuai Zhu; Ke Huang; Zhenhua Li; Phuong-Uyen C Dinh; Junqing Gao; Yi Zhang; Ke Cheng
Journal:  Adv Sci (Weinh)       Date:  2020-11-19       Impact factor: 16.806

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.