Literature DB >> 15584482

Estimation of the macromolecular proton fraction and bound pool T2 in multiple sclerosis.

G R Davies1, D J Tozer, M Cercignani, A Ramani, C M Dalton, A J Thompson, G J Barker, P S Tofts, D H Miller.   

Abstract

This study used a model for magnetization transfer (MT) to estimate two underlying parameters: the macromolecular proton fraction (f) and the bound pool T2 (T2b) in patients with multiple sclerosis (MS). Sixty patients with clinically definite MS and 27 healthy controls were imaged using: (1) a dual echo fast spin echo sequence, (2) a MT sequence (with ten MT power and offset frequency combinations) and (3) proton density and T1 weighted sequences (for T1 relaxation time estimation). Fourteen normal-appearing white matter (NAWM) regions of interest (ROI) and six normal-appearing gray matter (NAGM) ROIs were outlined in all subjects. Lesions were also contoured in subjects affected by MS. The model was fitted to the data leading to estimates of T2b and f. Results showed that T2b was increased in lesions whereas f was reduced. In NAWM, f was decreased while T2b was only increased in secondary progressive MS. NAWM f correlated modestly with disability. Further studies are needed to investigate the pathological basis of the abnormalities observed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15584482     DOI: 10.1191/1352458504ms1105oa

Source DB:  PubMed          Journal:  Mult Scler        ISSN: 1352-4585            Impact factor:   6.312


  19 in total

1.  Quantitative MR imaging of two-pool magnetization transfer model parameters in myelin mutant shaking pup.

Authors:  Alexey Samsonov; Andrew L Alexander; Pouria Mossahebi; Yu-Chien Wu; Ian D Duncan; Aaron S Field
Journal:  Neuroimage       Date:  2012-06-01       Impact factor: 6.556

Review 2.  Methodology of diffusion-weighted, diffusion tensor and magnetisation transfer imaging.

Authors:  S J Price; D J Tozer; J H Gillard
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

3.  MTR variations in normal adult brain structures using balanced steady-state free precession.

Authors:  Meritxell Garcia; Monika Gloor; Oliver Bieri; Stephan G Wetzel; Ernst-Wilhelm Radue; Klaus Scheffler
Journal:  Neuroradiology       Date:  2010-05-18       Impact factor: 2.804

4.  Effects of formalin fixation on magnetic resonance indices in multiple sclerosis cortical gray matter.

Authors:  Klaus Schmierer; Janet R Thavarajah; Shu F An; Sebastian Brandner; David H Miller; Daniel J Tozer
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

Review 5.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

6.  Spectral characteristics of semisolid protons in human brain white matter at 7 T.

Authors:  Xu Jiang; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2017-02-02       Impact factor: 4.668

Review 7.  Characterization of cerebral white matter properties using quantitative magnetic resonance imaging stains.

Authors:  Andrew L Alexander; Samuel A Hurley; Alexey A Samsonov; Nagesh Adluru; Ameer Pasha Hosseinbor; Pouria Mossahebi; Do P M Tromp; Elizabeth Zakszewski; Aaron S Field
Journal:  Brain Connect       Date:  2012-01-27

8.  Effects of magnetization transfer on T1 contrast in human brain white matter.

Authors:  Peter van Gelderen; Xu Jiang; Jeff H Duyn
Journal:  Neuroimage       Date:  2015-12-24       Impact factor: 6.556

9.  Rapid measurement of brain macromolecular proton fraction with transient saturation transfer MRI.

Authors:  Peter van Gelderen; Xu Jiang; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2016-06-25       Impact factor: 4.668

10.  Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain.

Authors:  Klaus Schmierer; Daniel J Tozer; Francesco Scaravilli; Daniel R Altmann; Gareth J Barker; Paul S Tofts; David H Miller
Journal:  J Magn Reson Imaging       Date:  2007-07       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.